Search NASA⌕ Search

Engineering topics

Zuo, Wangda

Publications and source records attributed to Zuo, Wangda.

At least 55 records · Page 3

Enhancing the Implementation of a First-order Equivalent Thermal Parameter Model to Enable Accurate and Robust Building Thermal Response Prediction

Predicting indoor temperature conditions are often necessary for advanced building controls. Gray-box models are preferable to do so because they can over- come limitations of white-box and black-box models; however, their current implementation methods can be problematic due to their difficulties in capturing non-linear behaviors and time-varying disturbances. This paper proposes a novel method to implement a popular gray-box model, the 1st-order equivalent thermal parameter (ETP) model. To evaluate performance, we applied the proposed method to predict in- door temperatures for a medium-office building, over the course of one day. Predictions are compared against two existing methods: the ETP model implemented through a common approach and a black-box model. Results suggest that the proposed method can yield more accurate results compared to the other methods; additionally, the proposed method demonstrated similar capabilities in capturing non-linear behaviors as the black-box model.

Hinkelman, Kathryn↗

Optimization of Workload Distribution of Data Centers Based on a Self-Learning In Situ Adaptive Tabulation Model

Data center cooling typically involves non-uniform airflow and temperature distributions, which are affected by the IT workload distribution. It is helpful to simulate the airflow and temperature to optimize the workload distribution. Traditional computational fluid dynamics (CFD) simulation is usually time-consuming while conventional reduced order models (ROMs), though computationally fast, may generate inaccurate results even after being fully trained. In Situ Adaptive Tabulation (ISAT), contracting to conventional ROM, can make prediction with error lower than a user-specified tolerance. To demonstrate using of ISAT for optimal workload distribution in data center, this paper presents a preliminary study of an ISAT-based genetic algorithm optimization platform. The ISAT is trained offline by using the results from CFD simulations using a hypothetical simple data center. The optimal workload distribution determined by the platform leads to approximately 6.8% of energy savings when compared to the benchmark with a uniform workload distribution. We note that the time cost for the entire optimization process, including the training of ISAT is about 4 hours, which is acceptable in the design phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Accurate Fast Fluid Dynamics Model for Data Center Applications

Traditional CFD is broadly useful in the design and operation of reliable and efficient data centers. It is nevertheless computationally expensive, particularly when employed for design optimization, which usually requires multiple simulations. To speed-up calculations while retaining essential airflow physics, several researchers have turned to an alternative CFD methodology, namely, fast fluid dynamics (FFD). FFD has been reported to be much faster than traditional CFD, but at an assumed (acceptable) trade-off of reduced accuracy. However, a recent comparison of FFD and traditional CFD for data center plenum applications produced nearly indistinguishable results and suggested that previously-reported FFD/traditional-CFD differences were due primarily to inconsistent: 1) advection schemes, 2) computational grids, and 3) turbulence models. The present paper extends this FFD/traditional-CFD comparison to the data center whitespace and confirms the finding that a true like-for-like comparison produces nearly identical predictions. Our FFD implementation utilizes a first-order upwind finite-volume scheme for advection like traditional CFD, so alternative advection schemes (e.g., semi-Lagrangian) are not considered further here. Likewise, the effect of grid choice on traditional-CFD predictions is well known. However, the effect of turbulence model for data center applications has not been reported extensively so we do consider this topic further here. We compare the standard k-e and a simpler algebraic model to benchmark experimental data from a real data center. We find that the algebraic turbulence model predicts rack-inlet temperatures at a similar level-of-accuracy as the k-e model for our fairly-simple-airflow reference data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Methodology to Create Prototypical Building Energy Models for Existing Buildings: A Case Study on U.S. Religious Worship Buildings

Prototypical building energy models are of great significance because they are the starting point in conducting analyses for various applications, such as building energy saving potential analysis, building design, building energy market evaluation, and building energy policy-making. However, current prototypical building energy models only represent limited types of buildings in certain countries. To fill the gap, this paper proposes a methodology to systematically create prototypical building energy models. First, a six-step methodology is introduced: model input identification, data collection, data cleaning, data conversion, model simulation, and model calibration. Then, the methodology is demonstrated by a case study of creating 30 prototypical energy models for U.S. religious worship buildings, representing buildings in 15 climate zones and 2 vintages (pre- and post-1980). Finally, to show the applications of the models, the building energy saving potentials from six efficiency measures are analyzed for pre-1980 U.S. religious worship buildings in three ASHRAE Climate Zones. The results show that the maximum energy saving potentials are approximately 30% for the religious worship buildings in all three climate zones investigated.

prototype building model, building simulation, Bui↗

An Optimization Platform Based on Coupled Indoor Environment and HVAC Simulation and its Application in Optimal Thermostat Placement

Model-based optimization can help improve the indoor thermal comfort and energy efficiency of Heating, Ventilation and Air Conditioning (HVAC) systems. The models used in previous optimization studies either omit the dynamic interaction between indoor airflow and HVAC or are too slow for model-based optimization. To address this limitation, we propose an optimization methodology using coupled simulation of the airflow and HVAC that captures the dynamics of both systems. We implement an optimization platform using the coupled models of a coarse grid Fast Fluid Dynamics model for indoor airflow and Modelica models for HVAC which is linked to the GenOpt optimization engine. Then, we demonstrate the new optimization platform by studying the optimal thermostat placement in a typical office room with a VAV terminal box in the design phase. After validating the model, we perform an optimization study, in which the VAV terminal box is dynamically controlled, and find that our optimization platform can determine the optimal location of thermostat to achieve either best thermal comfort or least energy consumption, or the combined. Finally, the time cost for performing such optimization study is about 6.2 h, which is acceptable in the design phase.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Equation-based object-oriented modeling and simulation of data center cooling systems

In this paper, we introduce a newly developed open source data center package in the Modelica Buildings library to support modeling and simulation of cooling and control systems of data centers. The data center package contains major thermal and control component models, such as Computer Room Air Handler, Computer Room Air Conditioner, models of different subsystem configurations such as chillers with differently configured waterside economizers, as well as templates for different systems. Two case studies based on this package are performed to investigate the performances of the cooling and electrical system under normal conditions and emergency situations such as a blackout: one is for a data center powered by conventional energy, and the other is for a data center powered by renewable energy. Simulation results show that the dynamic modeling and multi-domain simulation in the Modelica-based tool make it convenient for users to investigate both normal and emergent operations for conventional and renewable data centers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Open Source Modeling Framework for Interdependent Energy-Transportation-Communication Infrastructure in Smart and Connected Communities

Infrastructure in future smart and connected communities is envisioned as an aggregate of public services, including energy, transportation, and communication systems, all intertwined with each other. The intrinsic interdependency among these systems may exert the underlying influence on both design and operation of the heterogeneous infrastructures. Yet, few prior studies have tapped into the interdependency among these systems in order to quantify their potential impacts during standard operation. In response to this, this paper proposes an open-source, flexible, integrated modeling framework suitable for designing coupled energy, transportation, and communication systems and for assessing the impact of their interdependencies. First, a novel multi-level, multi-layer, multi-agent approach is proposed to enable flexible modeling of the interconnected systems. Then, for the framework's proof of concept, preliminary component and system-level models for different systems are designed and implemented using Modelica, an equation-based object-oriented modeling language. Finally, three case studies of gradually increasing complexity are presented (energy, energy + transportation, and energy + transportation + communication) to evaluate the interdependencies among the three systems. Quantitative analyses show that the deviation of the average velocity on the road can be 10.5% and the deviation of the power drawn from the grid can be 7% with or without considering the transportation and communication system at the peak commute time, indicating the presence of notable interdependencies. The proposed modeling framework also has the potential to be further extended for various modeling purposes and use cases, such as dynamic modeling and optimization, resilience analysis, and integrated decision making in future connected communities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling Power System Dynamics and Building Dynamics to Enable Building-to-Grid Integration

The interactions between power system dynamics and building dynamics are usually ignored or over-simplified in existing power systems and building modeling and simulation tools, which limits how system modeling can sup-port Building-to-Grid integration. This paper discusses a new approach to consider those interactions by model-ing motor-driven building devices or systems. The motor-driven model is based on simplified mechanical rotation equations and allows us to study the coupling relationship between frequency/voltage in the power system and motor-driven device operation. This model is validated by performing one proof-of-concept case study with Modelica. The simulation results suggest that the proposed model can yield better representations of these interactions than the existing simplified models, especially the ones with the fast transient dynamics.

Buildings-to-grid integration, motor, coupling sim↗

A New Fast Fluid Dynamics Model for Data-Center Floor Plenums

A raised-floor plenum is often used to distribute cooling airflow in data centers. Traditional Computational Fluid Dynamics (CFD) can accurately model airflow distribution in plenums, but it is expensive (computationally and financially) and is, therefore, often not accessible to the data center designer or operator. This paper presents an alternative CFD methodology based on Fast Fluid Dynamics (FFD), which is faster, more parallelizable, and simpler to program. The improvement in computational speed afforded by FFD is particularly important for multiple-iteration optimization, transient simulations, or applications for which near-real-time performance is required. Here, the potential speed improvements of FFD have been widely documented; however, it has been generally accepted that this benefit is accompanied by a modest loss of accuracy relative to traditional CFD. We show here that this is not necessarily true. Plenum airflow predictions by our FFD implementation, which utilizes a first-order upwind rather than Semi-Lagrangian advection scheme of previous research, are extremely close to those predicted by traditional CFD - provided the same turbulence model and computational grid are used consistently.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An agent-based hardware-in-the-loop simulation framework for building controls

In general, a hardware-in-the-loop (HIL) building simulation has lower cost and fewer practical limitations (e.g., scheduling issues) than field tests in occupied buildings, while also overcoming limitations of simulations alone by capturing the full behavior of some physical systems, equipment, and components. However, the implementation of an HIL can be difficult due to the scarcity of appropriate tools. Here, this paper presents an agent-based framework for HIL simulation. It can be used for investigation of controller performance via controller-in-the-loop simulations and also HIL for system synthesis. In the latter case, both controllers and major equipment participate in tests to ensure that dynamics of equipment operation are correctly captured in addition to controller performance. The HIL simulation framework presented allows such actual physical parts to be included in the framework while representing others for which behaviors are better known and modeled in simulation models. The mechanism implemented in the framework to synchronize simulations in software with real-time operation of physical equipment is described. Lastly, as an example, use of the HIL simulation framework is illustrated through a brief study of speed control of the supply fan in the air handling unit of a variable-air-volume building heating, ventilating and air-conditioning system.

42 ENGINEERING↗

Modelica Models for Data Center Cooling Systems

This paper presents a package of Modelica models, which are dedicated to data center cooling systems and recently added to the Modelica Buildings library. To demonstrate the usage of this package, we modeled a chilled water system with an integrated wateside economizer, and an air-cooled direct expansion system with an airside economizer. These models are then applied to evaluate the control performance. After that we performed a detailed comparison in terms of system-level energy efficiency, economizing hours and supply air conditions for the two cooling systems. The advantages and disadvantages of this package are finally summarized and discussed.

Fu, Yangyang↗

Building energy simulation coupled with CFD for indoor environment: A critical review and recent applications

This paper presents a comprehensive review of the open literature on motivations, methods and applications of linking stratified airflow simulation to building energy simulation (BES). First, we reviewed the motivations for coupling prediction models for building energy and indoor environment. This review classified various exchanged data in different applications as interface data and state data, and found that choosing different data sets may lead to varying performance of stability, convergence, and speed for the co-simulation. Second, our review shows that an external coupling scheme is substantially more popular in implementations of co-simulation than an internal coupling scheme. The external coupling is shown to be generally faster in computational speed, as well as easier to implement, maintain and expand than the internal coupling. Third, the external coupling can be carried out in different data synchronization schemes, including static coupling and dynamic coupling. In comparison, the static coupling that performs data exchange only once is computationally faster and more stable than the dynamic coupling. However, concerning accuracy, the dynamic coupling that requires multiple times of data exchange is more accurate than the static coupling. Furthermore, the review identified that the implementation of the external coupling can be achieved through customized interfaces, middleware, and standard interfaces. The customized interface is straightforward but may be limited to a specific coupling application. The middleware is versatile and user-friendly but usually limited in data synchronization schemes. The standard interface is versatile and promising, but may be difficult to implement. Current applications of the co-simulation are mainly energy performance evaluation and control studies. Finally, we discussed the limitations of the current research and provided an overview for future research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupling fast fluid dynamics and multizone airflow models in Modelica Buildings library to simulate the dynamics of HVAC systems

Multizone models are widely used in building airflow and energy performance simulations due to their fast computing speed. However, multizone models assume that the air in a room is well mixed, consequently limiting their application. In specific rooms where this assumption fails, the use of computational fluid dynamics (CFD) models may be an alternative option. Previous research has mainly focused on coupling CFD models and multizone models to study airflow in large spaces. While significant, most of these analyses did not consider the coupled simulation of the building airflow with the building’s Heating, Ventilation, and Air-Conditioning (HVAC) systems. This paper tries to fill the gap by integrating the models for HVAC systems with coupled multizone and CFD simulations for airflows, using the Modelica simulation platform. To improve the computational efficiency, we incorporated a simplified CFD model named fast fluid dynamics (FFD). We first introduce the data synchronization strategy and implementation in Modelica. Then, we verify the implementation using two case studies involving an isothermal and a non-isothermal flow by comparing model simulations to experiment data. Afterward, we study another three cases that are deemed more realistic. Furthermore, this is done by attaching a variable air volume (VAV) terminal box and a VAV system to previous flows to assess the capability of the models in studying the dynamic control of HVAC systems. Finally, we discuss further research needs on the coupled simulation using the models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast and self-learning indoor airflow simulation based on in situ adaptive tabulation

Fast simulation for stratified indoor airflow distributions is desired for various applications, such as design of advanced indoor environments, emergency management, and coupled annual energy simulation for buildings with stratified air distributions. Reduced order models trained by pre-computed computational fluid dynamics results are fast, but their prediction may be inaccurate when applied for conditions outside the training domain. To overcome this limitation, we propose in this paper a fast and self-learning model based on an in situ adaptive tabulation (ISAT) algorithm, which is trained by a fast fluid dynamics (FFD) model as an example. The idea is that the ISAT will retrieve the solutions from an existing data set if the estimated prediction error is within a pre-defined tolerance. Otherwise, the ISAT will execute the FFD simulation, which is accelerated by running in parallel on a graphics processing unit, for a full-scale simulation. This paper systematically investigates the feasibility of the ISAT for indoor airflow simulations by presenting the ISAT-FFD implementation alongside results related to its overall performance. Using a stratified indoor airflow as an example, we evaluated how the training time of ISAT was impacted by four factors (training methods, error tolerances, number of inputs, and number of outputs). Then we demonstrated that a trained ISAT model can predict the key information for inputs both inside and outside the training domain. The ISAT was able to answer query points both inside and close to training domain using retrieve actions within a time less than 0.001 s for each query. In conclusion, we provided suggestions for using the ISAT for building applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling indoor airflow, HVAC, control and building envelope heat transfer in the Modelica Buildings library

Here, this paper describes a coupled dynamic simulation of an indoor environment with heating, ventilation, and air conditioning (HVAC) systems, controls and building envelope heat transfer. The coupled simulation can be used for the design and control of ventilation systems with stratified air distributions. Those systems are commonly used to reduce building energy consumption while improving the indoor environment quality. The indoor environment was simulated using the fast fluid dynamics (FFD) simulation programme. The building fabric heat transfer, HVAC and control system were modelled using the Modelica Buildings library. After presenting the concept, the mathematical algorithm and the implementation of the coupled simulation were introduced. The coupled FFD–Modelica simulation was then evaluated using three examples of room ventilation with complex flow distributions with and without feedback control. Lastly, further research and development needs were also discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acceleration of the matrix multiplication of Radiance three phase daylighting simulations with parallel computing on heterogeneous hardware of personal computer

Building designers are increasingly relying on complex fenestration systems to reduce energy consumed for lighting and HVAC in low energy buildings. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex fenestration systems. Depending on the configurations, the simulation can take hours or even days using a personal computer. This paper describes how to accelerate the matrix multiplication portion of a Radiance three-phase daylight simulation by conducting parallel computing on heterogeneous hardware of a personal computer. The algorithm was optimized and the computational part was implemented in parallel using OpenCL. The speed of new approach was evaluated using various daylighting simulation cases on a multicore central processing unit and a graphics processing unit. Based on the measurements and analysis of the time usage for the Radiance daylighting simulation, further speedups can be achieved by using fast I/O devices and storing the data in a binary format.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗