Carbon emission responsive building control: A case study with an all-electric residential community in a cold climate

In the United States, buildings account for 35% of total energy-related carbon dioxide emissions, making them important contributors to decarbonization. Carbon intensities in the power grid are time-varying and can fluctuate significantly within hours, so shifting building loads in response to the carbon intensities can reduce a building’s operational carbon emissions. This paper presents a rule-based carbon responsive control framework that controls the setpoints of thermostatically controlled loads responding to the grid’s carbon emission signals in real time. Based on this framework, four controllers are proposed with different combinations of carbon accounting methods and control rules. To evaluate their performance, we performed simulation studies using models of a 27-home, all-electric, net zero energy residential community located in Basalt, Colorado, United States. The carbon intensity data of four future years from the Cambium data set are adopted to account for the evolving resource mix in the power grid. Various performance metrics, including energy consumption, carbon emission, energy cost, and thermal discomfort, were used to evaluate the performance of the controllers. Sensitivity analysis was also conducted to determine how the control thresholds and intervals affect the controllers’ performance. Simulation results indicate that the carbon responsive controllers can reduce the homes’ annual carbon emissions by 6.0% to 20.5%. However, the energy consumption increased by 0.9% to 6.7%, except in one scenario where it decreased by 2.2%. Compared to the baseline, the change in energy cost was between –2.9% and 3.4%, and thermal discomfort was also maintained within an acceptable range. The little impact on energy cost and thermal discomfort indicates there are no potential roadblocks for customer acceptance when rolling out the controllers in utility programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Prediction Impact of the Space Level Occupancy Schedule for a Primary School

By using the same occupant schedule for all spaces, a building level occupancy schedule in building energy modelling can reduce the cost and time of data collection, especially for large-scale simulations or when detailed occupancy data cannot be obtained. However, by describing the unique occupancy status in each space, a space level schedule can better reflect real-world scenarios. This research investigates the energy prediction impact of a space level occupancy schedule for primary school modelling in 16 ASHRAE climate zones. The results show that when switched from a building level to a space level occupancy schedule, the energy prediction difference is between -1.0% and 0.8%. Generally, the predicted building energy consumption using a space level occupancy schedule is higher than when using a building level occupancy schedule in hot and warm climate zones, but lower in other climate zones.

building energy model↗

Long-term carbon emission reduction potential of building retrofits with dynamically changing electricity emission factors

Buildings account for approximately 36% of the United States' total carbon emissions and building retrofits have great potential to reduce carbon emissions. Current research adopts a constant electricity emission factor although it changes over time due to the increase of renewable energy generation. Here, to accurately predict emission reduction potential of building retrofits, this study develops a novel method by using dynamically changing electricity emission factors. Using medium office buildings as an example, we predicted emission reduction of eight building retrofit measures from 2020 to 2050 in five locations in the U.S. with distinct climates and renewable adoption rates. To evaluate emission reduction potential sensitivity to the compositions of electricity generation, five scenarios for renewable energy adoptions are investigated. The results reveal several new phenomena on emission reduction potential of building retrofits for medium offices in the U.S.: (1) it decreases from 2026 to 2050; (2) it has the same trend with coal usage; and (3) it reaches the maximum under the high renewable cost scenario. Based on the results, it is recommended that building retrofits should focus on 1) improving lighting and equipment efficiency; 2) locations with higher coal usage rate, and 3) buildings under the high renewable cost scenario. The new method can also be used for predicting emission reduction potential of the building sector in the U.S. by applying to other building types and regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The effect of building retrofit measures on CO2 emission reduction – A case study with U.S. Medium office buildings

Building retrofit has great potential to reduce CO2 emissions since buildings are responsible for 36% of emissions in the United States. Several existing studies have examined the effect of building retrofit measures on CO2 emission reduction. However, these studies oversimplified emission factors of electricity by adopting constant annual emission factors. This study uses hourly emission factors of electricity to analyze the effect of building retrofit measures on emission reduction using U.S. medium office buildings as an example. We analyzed CO2 emission reduction effects of eight building retrofit measures that related to envelop and mechanical system in five locations: Tampa, San Diego, Denver, Great Falls, and International Falls. The main findings are: (1) estimating CO2 emission reduction with constant emission factors overestimates the emission reduction for most measures in San Diego, while it underestimates the emission reduction for most measures in Denver and International Falls; (2) The same retrofit measure may have different effects in CO2 emission reduction depending on the climates. For instance, improving lighting efficiency and improving equipment efficiency have less impacts in emission reduction in cold climates than hot climates; and (3) The most energy efficient measure may not be the most emission efficient measure. For example, in Great Falls, the most energy efficient measure is improving equipment efficiency, but the most emission efficient measure is improving heating efficiency.

Lou, Yingli↗

Occupant Preference-Aware Load Scheduling for Resilient Communities

The load scheduling of resilient communities in the islanded mode is subject to many uncertainties such as weather forecast errors and occupant behavior stochasticity. To date, it remains unclear how occupant preferences affect the effectiveness of the load scheduling of resilient communities. This paper proposes an occupant thermal preference-aware load scheduler for resilient communities operating in the islanded mode. First, key resilience indicators are selected to quantify its impacts on the load scheduling of a resilient community. A deterministic model predictive control-based load scheduling framework is adopted as the baseline. Then, a chance-constrained controller is proposed to address the occupant-induced uncertainty in room temperature setpoints. Finally, the chance-constrained controller is compared with the deterministic controller on a virtual community testbed based on a real-world net-zero energy community in Florida, U.S. Results have shown that the proposed chance-constrained controller performs better in terms of serving occupants’ thermal preference and the required battery sizes compared to the deterministic controller with the presence of the assumed stochastic occupant behavior. This work indicates that it is necessary to consider the stochasticity of the occupant behavior when designing optimal load schedulers for resilient communities.

Wang, Jing↗

Modelica-based system modeling for studying control-related faults in chiller plants and boiler plants serving large office buildings

System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear

Huang, Sen↗

An Open-Source Virtual Testbed for a Real Net-Zero Energy Community

Net zero energy communities (NZECs) are critical to ensure sustainability and resilience of modernized power systems. System modeling helps overcome technical challenges in designing and operating NZECs. In this paper, we present the modeling work based on a real NZEC. Two sets of models are developed: higher-fidelity physics-based models considering the interaction between subsystems of the studied NZEC and capturing fast-dynamics; and lower-fidelity data-driven models requiring less resource to establish and/or run. All models are validated against measurements from this real NZEC. In addition, we create a simulation framework which streamlines the processes for simulation and thus allows using developed models to form a virtual testbed. To demonstrate the usage of the virtual testbed, a case study is conducted where a building-to-grid integration control is evaluated via simulation. The evaluation results suggest that the tested control significantly smooths the power draw of the studied community and doesn’t sacrifice the thermal comfort to a great extent.

Huang, Sen↗

Investigation of HVAC operation strategies for office buildings during COVID-19 pandemic

To minimize the indoor transmission of contaminants, such as the virus that can lead to COVID-19, buildings must provide the best indoor air quality possible. Improving indoor air quality can be achieved through the building's HVAC system to decrease any concentration of indoor contaminants by dilution and/or by source removal. However, doing so has practical downsides on the HVAC operation that are not always quantified in the literature. This paper develops a temporal simulation capability that is used to investigate the indoor virus concentration and operational cost of an HVAC system for two mitigation strategies: (1) supplying 100% outdoor air into the building and (2) using different HVAC filters, including MERV 10, MERV 13, and HEPA filters. These strategies are applied to a hypothetical medium office building consisting of five occupied zones and located in a cold and dry climate. We modeled the building using the Modelica Buildings library and developed new models for HVAC filtration and virus transmission to evaluate COVID-19 scenarios. We show that the ASHRAE-recommended MERV 13 filtration reduces the average virus concentration by about 10% when compared to MERV 10 filtration, with an increase in site energy consumption of about 3%. In contrast, the use of 100% outdoor air reduces the average indoor concentration by about an additional 1% compared to MERV 13 filtration, but significantly increases heating energy consumption. Use of HEPA filtration increases the average indoor concentration and energy consumption compared to MERV 13 filtration due to the high resistance of the HEPA filter.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Case Study on Condenser Water Supply Temperature Optimization with a District Cooling Plant

District cooling (DC) continues to proliferate due to increasing global cooling demands and economies of scale benefits; however, most district-scale modeling has focused on heating, and to the best of our knowledge, researchers have yet to model cooling plants featuring waterside economizers in DC settings. With the popular Modelica Buildings library expanding its capabilities to district scale, this study is one of the first to demonstrate how the open-source models can be used for detailed energy and control analysis of a DC plant. For a real-world case study, we developed and calibrated high-fidelity models for a DC system central plant at a college campus in Colorado, USA, and we optimized the condenser water supply temperature (CWST) setpoint for a DC plant across multiple time horizons using the Optimization library in Dymola. Results indicate that annual CWST optimization saves 4.7% annual plant energy, with less than 1% of additional energy savings gained through daily optimization. This confirms previous studies' findings that high frequency CWST optimizations are not necessary for the studied system.

chiller plant↗

An assessment of power flexibility from commercial building cooling systems in the United States

Understanding varying characteristics and aggregate potential of power flexibility from different building types considering regional diversity is critically important to actively engaging building resources in future eco-friendly, low-cost, and sustainable power systems. This paper presents a comprehensive characteristics analysis and potential assessment of the power flexibility from heating, ventilation, and air conditioning (HVAC) loads in commercial buildings in the U.S. using a simulation-based method. In this method, commercial buildings are first grouped by building types and climate regions. The U.S. Department of Energy Commercial Prototype Building Models are used to represent an average building in each group and are simulated to characterize corresponding power flexibility. Based on building survey data, the number of commercial buildings in each group is estimated and used to calculate aggregate power flexibility. It is found that HVAC loads in commercial buildings offer more flexibility for increasing power consumption than for decreasing it. The power consumption of commercial buildings in the U.S. can be increased by 46 GW and decreased by 40 GW on peak summer days. Among all commercial building types, standalone retail buildings provide the most absolute flexibility while the medium office buildings have the most flexibility as a percentage of the rated power consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An open source fast fluid dynamics model for data center thermal management

Although computational fluid dynamics (CFD) has been widely adopted to improve data center thermal management, the high computational demand limits its applications, such as multivariate optimal design and operation. Fast fluid dynamics (FFD), which has been applied for fast airflow simulation, shows great potential. However, few research applied FFD for optimal design and operation of data center thermal management. This research improves the FFD model for data centers and conducts a comprehensive evaluation and demonstration. First, the FFD model is improved by solving the advection and diffusion equations together using an upwind scheme instead of a semi-Lagrangian advection solver in the conventional FFD model. Second, new features for data centers are added, such as a pressure correction method to simulate plenum airflow and dynamic boundary conditions for IT racks. The new FFD model is first validated with two indoor environment cases and the results show that the new FFD model has slightly better overall prediction accuracy and faster speed compared to the conventional FFD model. It is also observed that both FFD models achieve acceptable accuracy, except for a few localized disparities with experimental data, which might be due to simplified handling of turbulence viscosity near the boundaries. Furthermore, validation with a real data center shows that the FFD model achieves a similar level of accuracy as CFD when compared to the experimental measurements with some level of uncertainties. It is then demonstrated for data center optimal design and operation, which saves 53.4–58.8% of annual energy while still meeting the thermal requirements. In conclusion, with a much faster speed and comparable accuracy compared to CFD, the FFD model parallelized on a graphics processing unit is promising for practical model-based data center early design and operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Renewable Resource Allocation and Load Scheduling of Resilient Communities

This paper presents a methodology for enhancing community resilience through optimal renewable resource allocation and load scheduling in order to minimize unserved load and thermal discomfort. The proposed control architecture distributes the computational effort and is easier to be scaled up than traditional centralized control. The decentralized control architecture consists of two layers: The community operator layer (COL) allocates the limited amount of renewable energy resource according to the power flexibility of each building. The building agent layer (BAL) addresses the optimal load scheduling problem for each building with the allowable load determined by the COL. Both layers are formulated as a model predictive control (MPC) based optimization. Simulation scenarios are designed to compare different combinations of building weighting methods and objective functions to provide guidance for real-world deployment by community and microgrid operators. The results indicate that the impact of power flexibility is more prominent than the weighting factor to the resource allocation process. Allocation based purely on occupancy status could lead to an increase of PV curtailment. Further, it is necessary for the building agent to have multi-objective optimization to minimize unserved load ratio and maximize comfort simultaneously.

model predictive control↗

Assessments of data centers for provision of frequency regulation

There are numerous opportunities for data centers to participate in demand response programs considering their large energy capacities, flexible working environments and workloads, redundant design and operation, etc. As a type of demand response, frequency regulation requires fast response, and its potential is not fully explored by data centers yet. This paper proposes a synergistic control strategy for data center frequency regulation which uses both IT and cooling systems. It combines power management techniques at the server level with control of the chilled water supply temperature to track the regulation signal from the electrical market. A frequency regulation flexibility factor is also proposed to increase the IT capacity for frequency regulation. The performance of the control strategy is studied through numerical simulations using an equation based object-oriented Modelica platform designed for data centers. Simulation results show that with well-tuned control parameters, data centers can provide frequency regulation service in both regulation up and down. The performance of data centers in providing frequency regulation service is largely influenced by the regulation capacity bid, frequency regulation flexibility factor, workload condition, and cooling mode of the cooling system, and not significantly influenced by the time constant of chillers. In addition, compared with a server-only control strategy, the proposed synergistic control strategy can provide an extra regulation capacity of 3% of the design power when chillers are activated. Here, when chillers are deactivated, both strategies have a similar regulation capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.