Zwiener, J. M.

Publications and source records attributed to Zwiener, J. M..

Science Data Report for the Optical Properties Monitor (OPM) Experiment

This science data report describes the Optical Properties Monitor (OPM) experiment and the data gathered during its 9-mo exposure on the Mir space station. Three independent optical instruments made up OPM: an integrating sphere spectral reflectometer, vacuum ultraviolet spectrometer, and a total integrated scatter instrument. Selected materials were exposed to the low-Earth orbit, and their performance monitored in situ by the OPM instruments. Coinvestigators from four NASA Centers, five International Space Station contractors, one university, two Department of Defense organizations, and the Russian space company, Energia, contributed samples to this experiment. These materials included a number of thermal control coatings, optical materials, polymeric films, nanocomposites, and other state-of-the-art materials. Degradation of some materials, including aluminum conversion coatings and Beta cloth, was greater than expected. The OPM experiment was launched aboard the Space Shuttle on mission STS-81 in January 1997 and transferred to the Mir space station. An extravehicular activity (EVA) was performed in April 1997 to attach the OPM experiment to the outside of the Mir/Shuttle Docking Module for space environment exposure. OPM was retrieved during an EVA in January 1998 and was returned to Earth on board the Space Shuttle on mission STS-89.

Wilkes, D. R.

Radiation Induced Degradation of White Thermal Control Paint

This paper details a comparison analysis of the zinc-oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 yr in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent Sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.

Radiation Induced Degradation of White Thermal Control Paint

This paper details a comparison analysis of the zinc-oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 yr in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent Sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.

Radiation Induced Degradation of White Thermal Control Paint

This paper details a comparison analysis of the Zinc Oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuum reflectance technique. The dose applied to the paints was approximately equivalent to 5 years in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuum reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectanc6 recovery after an additional 190 Equivalent Sun Hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.

Radiation Induced Degradation of the White Thermal Control Paints Z-93 and Z-93P

This paper details a comparison analysis of the zinc oxide pigmented white thermal control paints Z-93 and Z-93P. Both paints were simultaneously exposed to combined space environmental effects and analyzed using an in-vacuo reflectance technique. The dose applied to the paints was approximately equivalent to 5 years in a geosynchronous orbit. This comparison analysis showed that Z-93P is an acceptable substitute for Z-93. Irradiated samples of Z-93 and Z-93P were subjected to additional exposures of ultraviolet (UV) radiation and analyzed using the in-vacuo reflectance technique to investigate UV activated reflectance recovery. Both samples showed minimal UV activated reflectance recovery after an additional 190 equivalent sun hour (ESH) exposure. Reflectance response utilizing nitrogen as a repressurizing gas instead of air was also investigated. This investigation found the rates of reflectance recovery when repressurized with nitrogen are slower than when repressurized with air.

Edwards, D. L.

Fluorescence measurements of the thermal control experiments coatings on LDEF S0069 and A0114

Fluorescence measurements were made on the thermal control coatings from the Long Duration Experiment Facility (LDEF) S0069, Thermal Control Surfaces Experiment (TCSE); and the A0114, Interaction of Atomic Oxygen with Material Surfaces in Low Earth orbit. Fluorescence was observed in two types of thermal control coatings and is attributed to pigments or binders. In addition, fluorescence measurement on the silver Teflon from the front cover of TCSE led to confirmation of damage (cracking) to the metal layers during application.

Zwiener, J. M.

Environmental monitoring for Space Station WP01

External contamination monitoring instrumentation for the Space Station work package one (WP01) elements, were imposed on the contractor as deliverable hardware. The monitoring instrumentation proposed by the WP01 contractor in response to the contract requirement includes both real time measurements and passive samples. Real time measurement instrumentation consists of quartz crystal microbalances for molecular deposition, ion gaseous species identification. Internal environmental contamination monitoring for particulates is included in both Lab and HAB modules. Passive samples consists of four sample mounting plates mounted external to the Space Station modules, two on the U.S. LAB, and two on the HAB module.

Zwiener, J. M.

Research Furnace for Crystal Preparation

Three-zone furnace tested and characterized for preparation of lead-tintelluride (LTT) crystals. Tests show temperature in furnace controlled to obtain constant rate of movement of high-temperature isotherm down length of furnace. Temperature profiles accurately controlled by three independent heaters. Control software brings separate heaters to any desired temperature.

Crouch, R. K.

Real time reflectometer

A real time reflectometer with the particular utility of measuring fairly rapid (transient) changes in the specular reflectance of a sample which is continuously exposed to a perturbing environment is described. A fixed radiation source, a fixed detector, a uniformly rotating sample wheel, and a uniformly rotating optical wheel protect against misalignment problems. The reflectometer operates by comparing the measurings of a reflected signal with that of a reference signal made within fractions of a second of one another. Reflectance is measured in the infrared, visible, and vacuum ultraviolet regions.

Zwiener, J. M.

Measurement of transient reflectance

Real-time reflectometer, adjusted to a fraction of a second, monitors transient effects and allows sample to be exposed to environment continuously. Reflectance and reference signals share same optical path, minimizing extraneous effects.

Zwiener, J. M.

Optical contamination during thermal testing in vacuum

Comparative tests are described for optical degradation in vacuum systems served by oil-type or ion-type pumping operation. Results show that degradation occurs only during ultraviolet irradiation in vacuum systems with oil-type pumping systems and that it increases with exposure time. Degradation does not occur with ion systems.

Zwiener, J. M.