Abstract

A remote sensing oculometer was successfully operated during flight tests with a NASA experimental Twin Otter aircraft at the Langley Research Center. Although the oculometer was designed primarily for the laboratory, it was able to track the pilot's eye-point-of-regard (lookpoint) consistently and unobtrusively in the flight environment. The instantaneous position of the lookpoint was determined to within approximately 1 deg. Data were recorded on both analog and video tape. The video data consisted of continuous scenes of the aircraft's instrument display and a superimposed white dot (simulating the lookpoint) dwelling on an instrument or moving from instrument to instrument as the pilot monitored the display information during landing approaches.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Middleton, D. B., Hurt, G. J., Jr., Wise, M. A., Holt, J. D.. 1977-06-01. Description and flight tests of an oculometer. https://ntrs.nasa.gov/citations/19770019210