NASA NTRS · 19800010670
Some experience with arc-heater simulation of outer planet entry radiation
Abstract
An electric arc heater was operated at 800 amperes and 100,000 pa (1 atm) with hydrogen, helium, and two mixtures of hydrogen and helium. A VUV-scanning monochromator was used to record the spectra from an end view while a second spectrometer was used to determine the plasma temperature using hydrogen continuum radiation at 562 nm. Except for pure helium, the plasma temperature was found to be too low to produce significant helium radiation, and the measured spectra were primarily the hydrogen spectra with the highest intensity in the pure hydrogen case. A radiation computer code was used to compute the spectra for comparison to the measurements and to extend the study to simulation of outer planet entry radiation. Conductive cooling prevented ablation of phenolic carbon material samples mounted inside the arc heater during a cursory attempt to produce radiation absorption by ablation gases.
Keep this discovery
Explore connections, maps & timelines
Wells, W. L., Snow, W. L.. 1980-01-01. Some experience with arc-heater simulation of outer planet entry radiation. https://ntrs.nasa.gov/citations/19800010670
Cite the original work for its findings. Save a collection to share your selection of sources.