NASA NTRS · 19830051549
Space Shuttle base heating
Abstract
First-stage and second-stage heating environments of the base region of the Space Shuttle are characterized in detail in terms of Orbiter-main-engine-plume and booster-plume radiation, freestream-air convective cooling, and reversed-plume-flow convective heating as they affect each base-region design point. Design predictions are compared with selected heating-rate data from flights STS-1 through STS-5; the flight data are found to show excellent interflight repeatability independent of small changes in trajectory, and to verify the validity of the prediction methodology. The impact of individual flight events on base heating is indicated.
Keep this discovery
Explore connections, maps & timelines
Greenwood, T. F., Lee, Y. C., Bender, R. L., Carter, R. L.. 1983-06-01. Space Shuttle base heating. https://ntrs.nasa.gov/citations/19830051549