Search NASA⌕ Search

NASA NTRS · 19910070372

The JPL Molecular Contamination Investigation Facility

Abstract

The Molecular Contamination Investigation Facility (MCIF) is discussed in terms of its use for improving the far-UV performance of a camera and its broader applications. The MCIF incorporates two independent vacuum systems with sample isolation chambers and regulated heat exchangers as well as three quartz-crystal microbalances (QCMs) and a residual gas analyzer. One cryogenic QCM is heat sunk into an LN2 heat exchanger, while the others are thermoelectrically controlled and are heat sunk into a regulated heat exchanger. Outgas accumulation can be measured at three surface temperatures between -180 and 80 C simultaneously, and results are presented for the testing of 34 samples in a large-chambered system and 22 samples in a system with a smaller chamber. The MCIF results provide a database for fabrication processes, material selection, maximum bakeout temperatures, and the development of an ultraclean bakeout chamber.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Taylor, Daniel M., Soules, David, Osborn, David. 1990-01-01. The JPL Molecular Contamination Investigation Facility. https://ntrs.nasa.gov/citations/19910070372

Cite the original work for its findings. Save a collection to share your selection of sources.