Operation and design considerations for unsteady data acquisition with PC-based systems in high Reynolds number hypersonic flowfields
Abstract
Operation and design considerations for personal-computer-based data acquisition are analyzed, and a system is created that is portable, inexpensive, and capable of high-frequency response. This system performed well when given an extensive analysis of the characteristics of the radio-frequency noise in the test environment. The system architecture is well-suited for support of high-frequency data acquisition from both pressure transducers and high-frequency-response thermocouple gauges. As configured, the system provides a data resolution of approximately 0.09 psia and 0.56 F. Considering the constraints placed upon this design, this data resolution is acceptable. The $5000 budget did require use of an existing PC and rental of signal-conditioning equipment.