NASA NTRS · 20000054887
The Mars Development of a Micro-Isolation Valve
Abstract
A feasibility investigation for a newly proposed microfabricated, normally-closed isolation valve was initiated. The micro-isolation valve is silicon based and relies on the principle of melting a silicon plug, opening an otherwise sealed flow passage. This valve may thus serve a similar role as a conventional pyrovalve and is intended for use in micropropulsion systems onboard future microspacecraft, having wet masses of no more than 10-20 kg, as well as in larger scale propulsion systems having only low flow rate requirements, such as ion propulsion or Hall thruster systems. Two key feasibility issues - melting of the plug and pressure handling capability - were addressed. Thermal finite element modeling showed that valves with plugs having widths between 10 and 50 gm have power requirements of only 10 . 30 Watts to open over a duration of 0.5 ms or less. Valve chips featuring 5 0 micron plugs were burst pressure tested and reached maximum pressure values o f 2900 psig (19.7 Mpa).
Keep this discovery
Explore connections, maps & timelines
Mueller, Juergen, Vargo, Steven, Forgrave, John, Bame, David, Chakraborty, Indrani, Tang, William. 1999-01-01. The Mars Development of a Micro-Isolation Valve. https://ntrs.nasa.gov/citations/20000054887
Cite the original work for its findings. Save a collection to share your selection of sources.