Search NASA⌕ Search

NASA NTRS · 20150007416

FE Simulation of SMA Seal for Mars Sample Return

Abstract

Several NASA rovers and landers have been on Mars and performed successful in-situ exploration. Returning Martian samples to Earth for extensive analysis is of great interest to the planetary science community. Current Mars sample return architecture would require leaving the acquired samples on Mars for years before being retrieved by subsequent mission. Each sample would be sealed securely to keep its integrity. A reliable seal technique that does not affect the integrity of the samples and uses a simple low-mass tool is required. The shape memory alloy (SMA) seal technique is a promising candidate. A study of the thermal performances of several primary designs of a SMA seal for sample tubes by finite element (FE) simulation are presented in this paper. The results show sealing the sample tube by SMA plugs and controlling the sample temperature below the allowed temperature level are feasible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bao, Xiaoqi, Younse, Paulo, Bhandari, Pradeep. 2013-03-10. FE Simulation of SMA Seal for Mars Sample Return. https://ntrs.nasa.gov/citations/20150007416

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential

An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.

seal↗