Search NASA⌕ Search

NASA NTRS · 20150023074

The Structural Heat Intercept-Insulation-Vibration Evaluation Rig (SHIVER)

Abstract

NASA is currently investigating methods to reduce the boil-off rate on large cryogenic upper stages. Two such methods to reduce the total heat load on existing upper stages are vapor cooling of the cryogenic tank support structure and integration of thick multilayer insulation systems to the upper stage of a launch vehicle. Previous efforts have flown a 2-layer MLI blanket and shown an improved thermal performance, and other efforts have ground-tested blankets up to 70 layers thick on tanks with diameters between 2 3 meters. However, thick multilayer insulation installation and testing in both thermal and structural modes has not been completed on a large scale tank. Similarly, multiple vapor cooled shields are common place on science payload helium dewars; however, minimal effort has gone into intercepting heat on large structural surfaces associated with rocket stages. A majority of the vapor cooling effort focuses on metallic cylinders called skirts, which are the most common structural components for launch vehicles. In order to provide test data for comparison with analytical models, a representative test tank is currently being designed to include skirt structural systems with integral vapor cooling. The tank is 4 m in diameter and 6.8 m tall to contain 5000 kg of liquid hydrogen. A multilayer insulation system will be designed to insulate the tank and structure while being installed in a representative manner that can be extended to tanks up to 10 meters in diameter. In order to prove that the insulation system and vapor cooling attachment methods are structurally sound, acoustic testing will also be performed on the system. The test tank with insulation and vapor cooled shield installed will be tested thermally in the B2 test facility at NASAs Plumbrook Station both before and after being vibration tested at Plumbrooks Space Power Facility.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Johnson, W. L., Zoeckler, J. G., Best-Ameen, L. M.. 2015-06-24. The Structural Heat Intercept-Insulation-Vibration Evaluation Rig (SHIVER). https://ntrs.nasa.gov/citations/20150023074

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Validation & Verification of CFD Models for Cryogenic Fluid Management of Propellant Tanks in Space

This article describes the need and the strategy for CFD model development, validation, and verification for Cryogenic Fluid Management (CFM) of Propellant Tanks in Space. It describes the type of CFD models that must be developed to address the future needs of Space CFM. It also discusses the two classes of experiments currently used to validate the fidelity of the CFD models. These two experiment classes are: (a) the small-scale simulant fluid science experiments that are equipped with scientific diagnostics to elucidate the underlying two-phase fluid physics of the CFM processes; and (b) the large-scale cryogenic experiments that assess the engineering performance of the propellant tank for storage and transfer. The current status of the CFD model development and validation is briefly assessed by presenting examples of segregated two-phase flow problems that have been successfully modeled. The future model development directions for CFM situations involving more complex interpenetrating phases are also defined.

Cryogenic Fluid Management↗

Comparison of Liquefaction Testing with Liquid Nitrogen and Liquid Oxygen

Liquid nitrogen is often used as a substitute for oxygen testing due to safety concerns, and the general similarity between their fluid properties. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, an opportunity arose to compare liquid nitrogen and liquid oxygen behavior using the same test hardware in similar test conditions. Comparative testing would verify whether the system response to nitrogen and oxygen would behave in a similar manner. Tests that were investigated include system boil-off heat load determination, autogenous pressurization, cryocooler loop initiation, and cryocooler loop operations. Results from testing are shown and compared to verify that liquid nitrogen and liquid oxygen tests yield similar system responses, and that nitrogen can be used as a substitute for oxygen in developmental tests at cryogenic temperatures.

Cryogenic Fluid Management↗

Low Leakage Valves for Long Duration Missions

This paper presents a status update on the low leakage cryogenic test valves currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and preliminary results.

Cryogenic Fluid Management↗