The objective of this project is to define torque values for bolts and screws when loading is not a concern. Fasteners require a certain torque to fulfill its function and prevent failure. NASA Glenn Research Center did not have a set of fastener torque tables for non-critical applications without loads, usually referring to hand-tight or wrench-tight torqueing. The project is based on two formulas, torque and pullout load. Torque values are calculated giving way to preliminary data tables. Testing is done to various bolts and metal plates, torqueing them until the point of failure. Around 640 torque tables were developed for UNC, UNF, and M fasteners. Different lengths of thread engagement were analyzed for the 5 most common materials used at GRC. The tables were put together in an Excel spreadsheet and then formatted into a Word document. The plan is to later convert this to an official technical publication or memorandum.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Rivera-Rosario, Hazel T., Powell, Joseph S.. 2017-04-01. Installation Torque Tables for Noncritical Applications. https://ntrs.nasa.gov/citations/20170003491

Cite the original work for its findings. Save a collection to share your selection of sources.