Search NASASearch

NASA NTRS · 20170004847

Gravity Effects in Microgap Flow Boiling

Abstract

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robinson, Franklin, Bar-Cohen, Avram. 2017-05-30. Gravity Effects in Microgap Flow Boiling. https://ntrs.nasa.gov/citations/20170004847

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Achieving High Efficiency in Reduced Order Modeling for Large Scale Polycrystal Plasticity Simulations

Reduced order models for the nonlinear response of heterogeneous microstructures typically require a construction (or training) stage to build the reduced order basis. In this manuscript, an efficient model construction strategy for the eigenstrain homogenization method (EHM) is presented. The proposed strategy relies on a parallel, element-by-element, conjugate gradient solver. Near linear scaling has been achieved with respect to the number of degrees of freedom used to resolve the microstructure. Linear scaling with respect to the number of pre-analyses required to construct the reduced order model (ROM) follows from the EHM formulation. Furthermore, a parallel implementation for fast evaluation of the constructed ROM has been developed using shared memory parallelization. It has been shown that for large microstructures with ≈ 10,000 grains, the total computational cost of evaluating the nonlinear response of a polycrystal could be reduced by approximately an order of magnitude using 32 cores with respect to serial ROM simulation. The present methodology has been verified using an additively manufactured polycrystalline microstructure of a nickel-based superalloy, Inconel 625. The capability of the developed framework to construct a ROM for such large microstructures, as well as the ability of the ROM to predict average and local quantities of interest has been demonstrated.

microscale

Gravity Effects in Microgap Flow Boiling

Increasing integration density of electronic components has exacerbated the thermal management challenges facing electronic system developers. The high power, heat flux, and volumetric heat generation of emerging devices are driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which facilitates direct contact between the heat-generating device and coolant flow. Microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel between devices. While two phase microcoolers are used routinely in ground-based systems, the lack of acceptable models and correlations for microgravity operation has limited their use for spacecraft thermal management. Previous research has revealed that gravitational acceleration plays a diminishing role as the channel diameter shrinks, but there is considerable variation among the proposed gravity-insensitive channel dimensions and minimal research on rectangular ducts. Reliable criteria for achieving gravity-insensitive flow boiling performance would enable spaceflight systems to exploit this powerful thermal management technique and reduce development time and costs through reliance on ground-based testing. In the present effort, the authors have studied the effect of evaporator orientation on flow boiling performance of HFE7100 in a 218 m tall by 13.0 mm wide microgap cooler. Similar heat transfer coefficients and critical heat flux were achieved across five evaporator orientations, indicating that the effect of gravity was negligible.

microscale