Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscale”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design of nematic liquid crystals to control microscale dynamics

The dynamics of small particles, both living such as swimming bacteria and inanimate, such as colloidal spheres, has fascinated scientists for centuries. If one could learn how to control and streamline their chaotic motion, that would open technological opportunities in the transformation of stored or environmental energy into systematic motion, with applications in micro-robotics, transport of matter, guided morphogenesis. This review presents an approach to command microscale dynamics by replacing an isotropic medium with a liquid crystal. Orientational order and associated properties, such as elasticity, surface anchoring, and bulk anisotropy, enable new dynamic effects, ranging from the appearance and propagation of particle-like solitary waves to self-locomotion of an active droplet. By using photoalignment, the liquid crystal can be patterned into predesigned structures. In the presence of the electric field, these patterns enable the transport of solid and fluid particles through nonlinear electrokinetics rooted in anisotropy of conductivity and permittivity. Director patterns command the dynamics of swimming bacteria, guiding their trajectories, polarity of swimming, and distribution in space. This guidance is of a higher level of complexity than a simple following of the director by rod-like microorganisms. Namely, the director gradients mediate hydrodynamic interactions of bacteria to produce an active force and collective polar modes of swimming. The patterned director could also be engraved in a liquid crystal elastomer. When an elastomer coating is activated by heat or light, these patterns produce a deterministic surface topography. The director gradients define an activation force that shapes the elastomer in a manner similar to the active stresses triggering flows in active nematics. Finally, the patterned elastomer substrates could be used to define the orientation of cells in living tissues. The liquid-crystal guidance holds a major promise in achieving the goal of commanding microscale active flows.

36 MATERIALS SCIENCE↗

Liquid–Solid Mixtures of Ga Metal Infused with Cu Microparticles and Nanoparticles for Microscale and Nanoscale Patterning of Solid Metals at Room Temperature

This paper demonstrates and characterizes a simple ink for nanopatterning of solid metallic structures under ambient conditions by taking advantage of the low melting point of gallium and its affinity to form intermetallics with other metals. Bare copper micro- and nanoparticles readily mix with liquid gallium near room temperature to form a paste that ultimately amalgamates into a dense solid when mixed at the appropriate concentration ratios. The paste has sufficient shelf life that can be extruded from a nozzle at modest temperatures to form solid three-dimensional (3D) shapes. Additionally, the paste can be molded at room temperature to replicate feature sizes ranging from a few millimeters down to hundreds of nanometers. In situ X-ray diffraction (XRD) and thermo-mechanical analysis (TMA) data show gallium and copper readily interdiffuse to form the thermodynamically expected intermetallic phase. We describe the capabilities and limitations of a simple way to pattern solid metals in an additive fashion (syringe-based extrusion) and with high resolution (molding) at or near room temperature. Here, the use of a paste that solidifies provides a novel route for 3D printing of solid metals at ambient temperatures as well as the creation of micro- and nanostructured metallic surfaces that may be useful for optics, non-wetting surfaces, or electronic microcomponents.

36 MATERIALS SCIENCE↗

Microscale Digital Vacuum Electronic Gates

Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.

Manohara, Harish↗

Active- and transfer-learning applied to microscale-macroscale coupling to simulate viscoelastic flows

Active- and transfer-learning are applied to microscale dynamics of polymer flows for the multiscale discovery of effective constitutive approximations required in viscoelastic flow simulation. The result is macroscopic rheology directly connected to a microstructural model. Micro and macroscale simulations are adaptively coupled by means of Gaussian process regression (GPR) to run the expensive microscale computations only as necessary. This multiscale method is demonstrated with flows of a polymer solution as a model system. At the microscale level dissipative particle dynamics (DPD) is employed to model the fluid as a suspension of bead-spring micro-structures subjected to steady shear flow. The results yield the non-Newtonian viscosity and the first normal stress difference at strain rates as training data used in a GPR model. DPD parameters are calibrated with respect to experimental data for a real polymer solution. Compliance with these data requires adjustment of the DPD model's cutoff radius, which then becomes a function of the second invariant of the strain rate tensor. The FENE-P model is chosen for the macroscale description using the spectral element method (SEM) to simulate channel flow and flow past a circular cylinder. The DPD results at the lowest possible shear strain rate yield an estimate of the zero-shear rate viscosity, which allows the initiation of the macroscale flow by SEM as a Newtonian fluid. The resulting strain-rate field is surveyed to determine additional shear strain rate sampling points for the DPD system. This new information allows an initial fitting of parameters of the constitutive equation followed by new SEM simulations at the macroscale. Additionally, guided by active-learning GPR to select new sampling points, this process continues until convergence is achieved. The effectiveness of this new simulation paradigm for viscoelastic flows is tested with different macroscale operating conditions. The effective closure learned in the channel simulation is then transferred directly to the flow past a circular cylinder at low Reynolds number, where the results show that only two additional DPD simulations are required to achieve a satisfactory constitutive model. With an increase of the Reynolds number, the active-learning scheme automatically detects the inaccuracy of the learned constitutive model, and initiates additional DPD simulations for the extra data needed to once again close the microscale-macroscale coupled system. This new paradigm of active- and transfer-learning for multiscale modeling is readily applicable to other microscale-macroscale coupled simulations of complex fluids and other materials. Furthermore, the coupling between microscale and macroscale solvers can be seamlessly implemented with our open source multiscale universal interface (MUI) library.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscale Mechanical‐Chemical Modeling of Granular Salt: Insights for Creep

Abstract Microscale numerical modeling is potentially an effective approach for understanding salt creep, but it is quite challenging because natural salt grain boundaries can have complex and evolving geometry, and because contacts between these deformable salt mineral grains are dynamic as a result of compaction, chemical reaction, fluid flow, and heat transfer. In this study, we have overcome these challenges and developed a new microscale mechanical‐chemical (MC) model to analyze creep of salt at the microscale, accounting for coupled deformation, dynamic contacts, and chemical reaction in granular systems with realistic geometric representations. The MC model was realized by linking a new microscale mechanical code based on the numerical manifold method (NMM) to a reactive transport code named Crunch. We simulated the processes of reorganization of the salt grains, microfracturing, and pressure solution that contribute to creep at larger scales. Based on this first quantitative microscale model, we found that sharp corners of mineral grains can dominate the contact dynamics, microfracturing, and pressure solution when salt is compacted, thus governing the structural changes and porosity loss of the system. We found that pressure solution, which preferentially dissolves sharp corners and edges, can lead to relatively high porosity loss in the system, thus playing an important role in the creep of salt. Our analysis shows that the dynamic changes of salt granular systems involving grain relocation and pressure solution can occur repeatedly and continuously, thus contributing to longer‐term creep of salt at larger scales.

58 GEOSCIENCES↗

Report of the Atmosphere to Electrons Land-Based Mesoscale-to-Microscale Coupling Project (FY2020)

The overall goal of the Mesoscale-to-Microscale Coupling (MMC) project is to improve coupling between mesoscale and microscale simulations via improved guidance and new strategies for setting up simulations and for the development of new tools that can be used across the community. Including the mesoscale forcing is critical to modeling the full energy transfer across scales in the atmosphere. The project-specific objectives include: 1) To apply rigorous verification and validation (V&V) techniques to the new modeling tools that are developed as part of the project to ensure the accuracy of our codes and results and to develop estimates of the relative uncertainty. 2) To improve computational performance of the coupled MMC models through the development of methods that can be used to reduce turbulence spin-up time and hence the size of computational domains. 3) To improve representation of the surface layer in microscale models to enhance simulations of hub-height wind speed. 4) To develop guidance for the community describing the best ways to couple mesoscale and microscale models, including specific spatial scales at which the handoff to the microscale model should occur. 5) To prepare documentation and a suite of software tools that can be used across the community. And 6) To transition MMC research to the offshore environment. Major progress was made in each of these areas during FY20. The land-based portion of the project is reported herein, while the offshore portion will be reported separately. The team continued to advance the MMC tools and methodologies as well as to document their performance in journal papers and conference presentations, although several planned conferences were cancelled due to the COVID-19 pandemic.

54 ENVIRONMENTAL SCIENCES↗

Microscale Constitutive Model Sensitivity on Multiscale Modeling of Fiber Reinforced Composites

Fiber reinforced composites are desirable in applications where low weight and high strength are needed, but are susceptible to microscale variability during manufacturing, making failure predictions difficult. The impact microscale variability has on macroscale mechanical response is difficult to predict due to the computational efficiency needed to simulate many, large, high fidelity, microscale models. In this study, a multiscale approach was taken to model 3-point bend, 4-point bend, and tensile experiments of a unidirectional composite from only having microstructure scans of these samples and constituent properties from literature. These scans were sampled with different sized windows, and statistically equivalent microstructures were generated, then simulated for stiffness, strength, and fracture toughness using an efficient micromechanical. Mesoscale models were created where element sizes equaled microstructure size, and properties were assigned through sampling of microscale simulation results. First, this study showed the effect of using Weibull scaling on constituent matrix strength on macroscale response. Then, a comparison was made between different element sizes and experiments. Finally, model dimensions were fixed, and the effect of randomly distributed local properties alone was examined. Results showed that the scatter of strength and stiffness in the experiments could be predicted well using images of the microscale fiber morphologies and that using stochastic properties produced a 3% coefficient of variation of strength for all experiments.

statistical microstructure↗

Enabling Microscale Processing: Combined Raman and Absorbance Spectroscopy for Microfluidic On-Line Monitoring

Microfluidics have many potential applications including characterization of chemical processes on a reduced scale, spanning the study of reaction kinetics using on-chip liquid–liquid extractions, sample pretreatment to simplify off-chip analysis, and for portable spectroscopic analyses. The use of in situ characterization of process streams from laboratory-scale and microscale experiments on the same chemical system can provide comprehensive understanding and in-depth analysis of any similarities or differences between process conditions at different scales. A well-characterized extraction of Nd(NO 3 ) 3 from an aqueous phase of varying NO 3– (aq) concentration with tributyl phosphate (TBP) in dodecane was the focus of this microscale study and was compared to an earlier laboratory-scale study utilizing counter current extraction equipment. Here, we verify that this same extraction process can be followed on the microscale using spectroscopic methods adapted for microfluidic measurement. Concentration of Nd (based on UV–vis) and nitrate (based on Raman) was chemometrically measured during the flow experiment, and resulting data were used to determine the distribution ratio for Nd. Extraction distributions measured on the microscale were compared favorably with those determined on the laboratory scale in the earlier study. Both micro-Raman and micro-UV–vis spectroscopy can be used to determine fundamental parameters with significantly reduced sample size as compared to traditional laboratory-scale approaches. This leads naturally to time, cost, and waste reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Benchmarking Microscale Ductility Measurements (Final Report of the Project DE-NE0008799)

Conventional macroscale experimentation is generally considered to be straightforward with few limitations. Conversely, micro/nanoscale experimentation presents numerous challenges in loading device design, sample preparation and handling, as well as accurate understanding of grain size and local texture effects on recorded measurements. Despite these challenges, nanopillar compression, MEMs based micro-tension, and nanoindentation approaches have been able to provide fundamental contributions to the understanding of material behavior at small lengthscales. However, the overarching shortcoming of these micro/nanoscale experimentation approaches, is the inability to directly translate measurements evaluated at the nm and µm length scales (e.g., hardness) to macroscale tensile material behavior (i.e., elastic modulus, yield strength, and ductility). The objectives of the proposed study are, 1) to establish best practices for obtaining tensile microscale ductility measurements, and 2) to validate methodologies to for comparing microscale ductility measurements to macroscale ductility measurements. In order to achieve these objectives, a multi-lengthscale, multi-temperature testing protocol and simulation framework are executed first on copper as a model material to validate the following approach, and second on reactor grade Zircaloy-2. Experiments are conducted on specimens extracted from the same test piece to ensure nominally identical grain size and texture from specimens to specimen. Motivated by the need to isolate the contribution of size-effects on obtained mechanical property measurements, specimens are manufactured with thicknesses at the micro- (1-10 µm), meso- (10-100's µm), and macroscales (sub-sized ASTM E8). In-situ full-field deformation techniques (scanning electron microscopy (SEM) grid methods and optical DIC) are incorporated into testing at each specimen length-scale to capture plasticity localization and evolution. Experimental testing for all specimens is conducted at both room temperature and elevated temperatures to probe the role of thermal activation on plastic deformation accommodation processes. Simulation efforts focus on examining the mechanical behavior of microscale specimens using a finite element approach with explicitly resolved grain morphologies, and an embedded crystal plasticity model. The cost-efficient implementation method allows for the modeling of a statistically significant number of both real (i.e., digital twin) and generated microstructures to obtain an understanding of the interrelationships between specimen microstructure and geometric variables (grain size, texture, specimen geometry, etc.) on microscale mechanical behavior.

36 MATERIALS SCIENCE↗

In-Situ Scanning Electron Microscope Experiments for Microscale Mechanical Testing and Validated Modeling of Fiber Reinforced Thermoplastics

A novel, in-situ, scanning electron microscope (SEM) mechanical testing capability for materials at the microscale which provides experimental validation to a machine learning (ML) toolset for full-field validation of physics-based micromechanics models is being developed by researchers at NASA Glenn Research Center. These are enabling technologies for the integration of multiscale digital twins for materials into system level models which will result in the improved performance, material discovery, reduced production cost and time, rapid characterization, and prognostic structural health monitoring (SHM) for materials and structures for extreme environments in support of NASA space exploration missions. In order to bridge the material structure-to-system gap for digital twins, physics-based models must be experimentally validated at multiple length scales. Seminal microscale experiments, conducted at the Air Force Research Laboratory (AFRL), were limited to transverse compression of single-layer, unidirectional thermoset polymer matrix composite (PMC) micropillar specimens [1]. The early phases of the current project followed those initial results and setup to reproduce the compression testing of PMC material on the custom-built piezoelectric actuated micromechanical testing rig built by MicroTesting Solutions LLC. In this work, samples of thermoplastic PMC material were first machined into 3 mm cubes, and then further machining and final milling was done using a Focused Ion Beam (FIB). The initial experiment was done on a pillar roughly 20 µm x 20 µm x 40 µm tall. Additional pillars were milled with final sizes ranging from 20 µm x 20 µm x 40 µm tall to 40 µm x 40 µm x 65 µm tall. A speckle pattern for in-situ full-field measurements using Digital Image Correlation (DIC) was applied with platinum, which was coated on the surface, and then the FIB was used to mill away some of the coating to produce an irregular pattern of Pt on the pillar surface. The samples were loaded into the custom testing rig and placed into the SEM and loaded under compression until failure. Images were collected in the SEM during testing. Post-processing of the images was conducted using DIC to obtain full-field displacement and strain measurements elucidating the role of the matrix as well as fiber-fiber interaction at the microscale within the composite subjected to compression loading well into the non-linear regime of the material. Moreover, the evolution of fiber-matrix debonding and matrix cracking is observed in-situ at the microscale. This data, along with images segmented with a newly developed ML toolset [2], was used to create and validate physics-based micromechanics models. An image of the failed micropillar is shown in Figure 1. The techniques developed in the initial compression experiment was tailored to the validation needs of the models and expanded to include different sized samples as well as possibly tension and fatigue.

Laura Wilson↗

Microscale Imaging of Thermal Conductivity Suppression at Grain Boundaries

Abstract Grain‐boundary engineering is an effective strategy to tune the thermal conductivity of materials, leading to improved performance in thermoelectric, thermal‐barrier coatings, and thermal management applications. Despite the central importance to thermal transport, a clear understanding of how grain boundaries modulate the microscale heat flow is missing, owing to the scarcity of local investigations. Here, thermal imaging of individual grain boundaries is demonstrated in thermoelectric SnTe via spatially resolved frequency‐domain thermoreflectance. Measurements with microscale resolution reveal local suppressions in thermal conductivity at grain boundaries. Also, the grain‐boundary thermal resistance – extracted by employing a Gibbs excess approach – is found to be correlated with the grain‐boundary misorientation angle. Extracting thermal properties, including thermal boundary resistances, from microscale imaging can provide comprehensive understanding of how microstructure affects heat transport, crucially impacting the materials design of high‐performance thermal‐management and energy‐conversion devices.

36 MATERIALS SCIENCE↗

Characterizing microscale signatures in uranium ore concentrates using electron probe microanalyzer

Impurities in uranium ore concentrates (UOCs) serve as forensic signatures of processing history and origin. Here, this study utilizes Electron Probe Microanalyzer (EPMA) to characterize microscale compositional and textural features in individual UOC particles from both commercial and bench-scale production. At the particle scale, multiple internal phases with distinct morphologies, chemical signatures, and stoichiometries are documented. Our data shows that chemical impurities are heterogeneously distributed within single particles and among particles within a sample. These microscale heterogeneities correlate with known processing histories, indicating that microscale signatures of early fuel cycle materials can provide valuable information for nuclear forensic material analysis.

organic↗

Engineering microscale systems for fully autonomous intracellular neural interfaces

Conventional electrodes and associated positioning systems for intracellular recording from single neurons in vitro and in vivo are large and bulky, which has largely limited their scalability. Further, acquiring successful intracellular recordings is very tedious, requiring a high degree of skill not readily achieved in a typical laboratory. We report here a robotic, MEMS-based intracellular recording system to overcome the above limitations associated with form-factor, scalability and highly skilled and tedious manual operations required for intracellular recordings. This system combines three distinct technologies: 1) novel microscale, glass-polysilicon penetrating electrode for intracellular recording, 2) electrothermal microactuators for precise microscale movement of each electrode and 3) closed-loop control algorithm for autonomous positioning of electrode inside single neurons. Here, we demonstrate the novel, fully integrated system of glass-polysilicon microelectrode, microscale actuators and controller for autonomous intracellular recordings from single neurons in the abdominal ganglion of Aplysia Californica (n = 5 cells). Consistent resting potentials (< –35 mV) and action potentials (> 60 mV) were recorded after each successful penetration attempt with the controller and microactuated glass-polysilicon microelectrodes. The success rate of penetration and quality of intracellular recordings achieved using electrothermal microactuators were comparable to that of conventional positioning systems. The MEMS-based system offers significant advantages: 1) reduction in overall size for potential use in behaving animals, 2) scalable approach to potentially realize multi-channel recordings and 3) a viable method to fully automate measurement of intracellular recordings. Furthermore, this system will be evaluated in vivo in future rodent studies.

42 ENGINEERING↗