This presentation covers the basis and challenges for radiation effects in electronic systems. The three main types of radiation effects in electronics are: 1) total ionizing dose (TID), 2) total non-ionizing dose (TNID) / displacement damage dose (DDD), and 3) single-event effect (SEE). Some content on relevant examples of effects, current concerns, and possible environmental model-driven solutions are also included.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pellish, Jonathan A.. 2017-10-01. Current Status and Future Challenges in Risk-Based Radiation Engineering. https://ntrs.nasa.gov/citations/20170011271

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Si5345, SY88422L, LT3482, and MSK130 components Total Ionizing Dose Test Report

The purpose of this test was to characterize the SI-5345, SY88422L, LT3482 and MSK130 parameter degradation for total dose response. The components are associated with REAG ID #21-024. In the test, each device was exposed to high dose rate (HDR) irradiation using gamma radiation. Device parameters such as leakage currents, timing, and overall chip health were investigated. These devices were tested for an interstellar mission on a trajectory between 0.9 AU and 5.3 AU with a 2.5-year mission, yielding an expected overall dose of 29 krad(Si)behind 1 mm of aluminum shielding (at 95% confidence; environment and dose determined through SPENVIS). This test report gives an initial look at candidate parts. Extremely small sample sizes (only 1 or 2 devices tested) do not allow consideration of part-to-part variability. High dose rates were used despite LT3482 and MSK130 having potential enhanced low dose rate sensitivity (ELDRS). Care should be taken in interpreting results given these limitations.

Total Ionizing Dose (TID)

U309 N-Channel Silicon Junction Field Effect Transistor Total Ionizing Dose Characterization Report

The purpose of this testing was to characterize the InterFET Corporation U309 for total dose response. This test shall serve as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. The U309 is a discrete Junction Field Effect Transistor (JFET). High dose rate (HDR) irradiations were performed in this test so that the device susceptibility to Total Ionizing Dose (TID) could be determined.

Total Ionizing Dose (TID)