LM193 Dual Differential Comparator Total Ionizing Dose Test Report

Abstract

The purpose of this test was to characterize the flight lot of Texas Instruments' LM193 (flight part number is 5962-9452601Q2A) for total dose response. This test served as the radiation lot acceptance test (RLAT) for the lot date code (LDC) tested. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) was determined.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Topper, Alyson, Forney, James, Campola, Michael. 2017-09-19. LM193 Dual Differential Comparator Total Ionizing Dose Test Report. https://ntrs.nasa.gov/citations/20180000707

Cite the original work for its findings. Save a collection to share your selection of sources.