Search NASA⌕ Search

NASA NTRS · 20180005484

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

Abstract

This paper reports results for a 7-point lean direct injector (LDI) array for a particular configuration. The LDI configuration in this study used a 60 degrees center pilot swirler and 52.5 degrees on the six outer swirlers. Chemiluminescence images of C2 and CH were collected at a frame rate of 25 Hz using an intensified CCD camera. Narrow bandwidth filters were coupled with the CCD camera in order to spectrally isolate C2 and CH signals. C2 was captured at 515 nm, and the CH signal was acquired at 430 nm. Six inlet conditions were considered in this study, all with the same inlet pressure, 75 psia, and same inlet temperature, 800 degcrees Fahrenheit. These conditions aimed to observe the effect of equivalence ratio, fuel staging, and reference velocity on C2 and CH emissions. Based on the chemiluminescence images, the changes in the inlet conditions was evident in both the pilot and outers. Additionally, the pilot (center injector element) appeared well isolated from the six outer elements under all test conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Capil, Tyler G., Tacina, Kathleen M., Hicks, Yolanda R.. 2018-05-20. Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications. https://ntrs.nasa.gov/citations/20180005484

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

Two different configurations of a 7-point lean direct injector array were investigated. Chemiluminescence images of C2* or CH* were collected during combustion tests for insight on flame structure for the two configurations. Several inlet conditions were tested by varying the equivalence ratio or reference velocity. For the center right-hand 60 degree and outer right-hand 52 degree outers, the chemiluminescence emanating from the central pilot appeared well isolated from the outers. At the same time, a hollow region below the pilot showed little fluctuation of chemiluminescence where a central recirculation zone was present during the non-reacting tests. The central left-hand 60 degree and outer right-hand 52 degree configuration displayed a narrower structure from the pilot compared to the flatter pilot observed in the other configuration. Additionally, the right-handed outer swirlers may be responsible for the asymmetry observed with the chemiluminescence images. Both configurations showed less variation in chemiluminescence intensity as the reference velocity was increased. This was likely due to better atomization and vaporization associated with higher fuel and air flow rates.

lean direct injection↗

Fundamental Study of a 7-Element Fuel Injector Configuration for Gas Turbine Combustors, a Look at Cold Flow and Burning Measurements

As part of a parametric study in which we vary swirler angle and orientation and look at their effect on fluid mixing and combustion, we examine one configuration of a 7-point lean direct injector by looking at the non-combusting 2-D velocity field using PIV (Particle Image Velocimetry), and combusting system for chemical species using chemiluminescent imaging and flame spectroscopy. The circular 7-point array consists of axial swirlers, with the center 60 degree counterclockwise swirler surrounded by six 52 degree clockwise swirlers. The velocity results for this configuration show that the outer swirlers serve to isolate the center flow field near the injector exit. A recirculation zone forms downstream of the center swirler, but not behind the outer swirlers. The combusting results also show an isolated zone directly downstream of the center injector. The flame spectra show variation in speciation of combustion species such as OH* and CH*, and as a function of position within the combustor.

lean direct injection↗

Swirl-Venturi Lean Direct Injection Combustion Technology for Low-NOx Aero Gas Turbine Engines

This paper summarizes research on the lean direct injection (LDI) combustor concept for aero-gas turbine combustors. The focus of this paper is one particular family of lean direct injection designs, swirl-venturi lean direct injection (SV-LDI). SV-LDI is characterized by the airpath: an air swirler followed by a converging-diverging venturi. For most SV-LDI configurations, a fuel injector is inserted through the center of the air swirler, with the fuel injector tip at or near the venturi throat. Several design variables were studied. These included fuel injector tip location, air swirler blade thickness, air swirler blade angle, and fuel-air mixer size. Moving the fuel injector tip slightly upstream or downstream of the venturi throat has at most a small impact on NOx emissions. Changing the blade thickness also does not affect NOx emissions. Changing the swirler blade angle has a significant effect on NOx emissions. Decreasing swirler blade angle, and thus decreasing swirl number, decreases the NOx emissions at lower flame temperatures (below about 1800 K). However, the slope of the NOx vs. flame temperature curve is higher for lower swirl numbers. Finally, decreasing the fuel-air mixer size initially decreases NOx emissions. However, there may be an optimum fuel-air mixer size below which NOx emissions do not continue to decrease.

lean direct injection↗