Combustion and Emissions Study Using a 7-Point Lean Direct Injector Array

This paper continues a parametric study in which we consider the effect of air swirler configuration on the flame structure and combustor performance using a circular 7-point Lean Direct Injector Array for gas turbine applications. The injector array consists of a center swirler element surrounded by six swirler elements. Parameters considered in this study include swirler angle (60° or 52°), handedness (co-swirling or counter-swirling) and center swirler offset. The primary focus considers flame stability, comparing four key air swirler configurations: for 1) fuel-lean flames; 2) high cold flow air reference velocity flames. We determined that the baseline swirler configuration had the best lean stability and could sustain the highest reference velocity. For this baseline configuration, we also compare the lean-blowout limits of four aircraft gas turbine reference fuels. With regard to lean blow-out, we determined that C4 could sustain the leanest flame, followed closely by A2. A1 was a poor performer.

gas turbine combustors

Combustion and Emissions Study Using a 7-Point Lean Direct Injector Array Focus on Flame Stability

This paper continues a parametric study in which we consider the effect of air swirler configuration on the flame structure and combustor performance using a circular 7-point Lean Direct Injector Array for gas turbine applications. The injector array consists of a center swirler element surrounded by six swirler elements. Parameters considered in this study include swirler angle (60° or 52°), handedness (co-swirling or counter-swirling) and center swirler offset. The primary focus considers flame stability, comparing four key air swirler configurations: for 1) fuel-lean flames; 2) high cold flow air reference velocity flames. We determined that the baseline swirler configuration had the best lean stability and could sustain the highest reference velocity. For this baseline configuration, we also compare the lean-blowout limits of four aircraft gas turbine reference fuels. With regard to lean blow-out, we determined that C4 could sustain the leanest flame, followed closely by A2. A1 was a poor performer.

fluid mixing

Pilot Injector Redesign to Reduce N+3 Cycle Emissions for a Gas-Turbine Combustor

An overview is given of an effort for the use of CFD analysis to complement design and configuration definition of third generation Lean-Direct Injection combustion concepts (LDI-3) for NASA’s N+3 program. The National Combustion Code (OpenNCC) was used to perform non-reacting and two-phase reacting flow computations for a three-cup, nineteen-element flame tube array with redesigned pilot injectors to improve spray and emissions characteristics when compared to a previous LDI-3 design. All computations were performed with a consistent approach to mesh-generation, spray modeling, ignition and kinetics modeling for a ‘medium-power’ cycle condition. Computational predictions of the aerodynamics of a new pre-filming pilot injector were used to arrive at an optimized aerothermal design that meets effective area and fuel-air mixing criteria. The newly designed pilot injectors were shown to provide considerable improvements in aerodynamic stability, flame-tube pattern factor and NOx emissions, when compared to the original design.

nitrogen oxides injectors

Pilot Injector Redesign to Reduce N+3 Cycle Emissions for a Gas-Turbine Combustor

An overview is given of an effort for the use of CFD analysis to complement design and configuration definition of third generation Lean-Direct Injection combustion concepts (LDI-3) for NASA's N plus 3 program. The National Combustion Code (OpenNCC) was used to perform non-reacting and two-phase reacting flow computations for a three-cup, nineteen-element flametube array with redesigned pilot injectors to improve spray and emissions characteristics when compared to a previous LDI-3 design. All computations were performed with a consistent approach to mesh-generation, spray modeling, ignition and kinetics modeling for a "medium-power" cycle condition. Computational predictions of the aerodynamics of a new pre-filming pilot injector were used to arrive at an optimized aerothermal design that meets effective area and fuel-air mixing criteria. The newly designed pilot injectors were shown to provide considerable improvements in aerodynamic stability, flame-tube pattern factor and NOx emissions, when compared to the original design.

Nitrogen Oxides

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

Two different configurations of a 7-point lean direct injector array were investigated. Chemiluminescence images of C2* or CH* were collected during combustion tests for insight on flame structure for the two configurations. Several inlet conditions were tested by varying the equivalence ratio or reference velocity. For the center right-hand 60 degree and outer right-hand 52 degree outers, the chemiluminescence emanating from the central pilot appeared well isolated from the outers. At the same time, a hollow region below the pilot showed little fluctuation of chemiluminescence where a central recirculation zone was present during the non-reacting tests. The central left-hand 60 degree and outer right-hand 52 degree configuration displayed a narrower structure from the pilot compared to the flatter pilot observed in the other configuration. Additionally, the right-handed outer swirlers may be responsible for the asymmetry observed with the chemiluminescence images. Both configurations showed less variation in chemiluminescence intensity as the reference velocity was increased. This was likely due to better atomization and vaporization associated with higher fuel and air flow rates.

lean direct injection

Fundamental Study of a 7-Element Fuel Injector Configuration for Gas Turbine Combustors, a Look at Cold Flow and Burning Measurements

As part of a parametric study in which we vary swirler angle and orientation and look at their effect on fluid mixing and combustion, we examine one configuration of a 7-point lean direct injector by looking at the non-combusting 2-D velocity field using PIV (Particle Image Velocimetry), and combusting system for chemical species using chemiluminescent imaging and flame spectroscopy. The circular 7-point array consists of axial swirlers, with the center 60 degree counterclockwise swirler surrounded by six 52 degree clockwise swirlers. The velocity results for this configuration show that the outer swirlers serve to isolate the center flow field near the injector exit. A recirculation zone forms downstream of the center swirler, but not behind the outer swirlers. The combusting results also show an isolated zone directly downstream of the center injector. The flame spectra show variation in speciation of combustion species such as OH* and CH*, and as a function of position within the combustor.

lean direct injection

Swirl-Venturi Lean Direct Injection Combustion Technology for Low-NOx Aero Gas Turbine Engines

This paper summarizes research on the lean direct injection (LDI) combustor concept for aero-gas turbine combustors. The focus of this paper is one particular family of lean direct injection designs, swirl-venturi lean direct injection (SV-LDI). SV-LDI is characterized by the airpath: an air swirler followed by a converging-diverging venturi. For most SV-LDI configurations, a fuel injector is inserted through the center of the air swirler, with the fuel injector tip at or near the venturi throat. Several design variables were studied. These included fuel injector tip location, air swirler blade thickness, air swirler blade angle, and fuel-air mixer size. Moving the fuel injector tip slightly upstream or downstream of the venturi throat has at most a small impact on NOx emissions. Changing the blade thickness also does not affect NOx emissions. Changing the swirler blade angle has a significant effect on NOx emissions. Decreasing swirler blade angle, and thus decreasing swirl number, decreases the NOx emissions at lower flame temperatures (below about 1800 K). However, the slope of the NOx vs. flame temperature curve is higher for lower swirl numbers. Finally, decreasing the fuel-air mixer size initially decreases NOx emissions. However, there may be an optimum fuel-air mixer size below which NOx emissions do not continue to decrease.

lean direct injection

Chemiluminescence Measurements in a Combustor Using a 7-Point Lean Direct Injector Array Configuration for Gas Turbine Engine Applications

This paper reports results for a 7-point lean direct injector (LDI) array for a particular configuration. The LDI configuration in this study used a 60 degrees center pilot swirler and 52.5 degrees on the six outer swirlers. Chemiluminescence images of C2 and CH were collected at a frame rate of 25 Hz using an intensified CCD camera. Narrow bandwidth filters were coupled with the CCD camera in order to spectrally isolate C2 and CH signals. C2 was captured at 515 nm, and the CH signal was acquired at 430 nm. Six inlet conditions were considered in this study, all with the same inlet pressure, 75 psia, and same inlet temperature, 800 degcrees Fahrenheit. These conditions aimed to observe the effect of equivalence ratio, fuel staging, and reference velocity on C2 and CH emissions. Based on the chemiluminescence images, the changes in the inlet conditions was evident in both the pilot and outers. Additionally, the pilot (center injector element) appeared well isolated from the six outer elements under all test conditions.

lean direct injection

Effect of Air Swirler Configuration on Lean Direct Injector Flow Structure and Combustion Performance with a 7-Point Lean Direct Injector Array

Studies of various injector configurations in a 7-point Lean Direct Injector (LDI) array are reported for both non-reacting (cold) flow and for Jet-A/air reacting flows. For cold flow, central recirculation zone (CRZ) formation is investigated and for reacting flows, combustor operability and dynamics are of interest. 2D Particle Image Velocimetry (PIV) measurements are described for the cold flow experiments and flame chemiluminescence imaging and dynamic pressure results are discussed for the reacting flow cases. PIV results indicate that for this configuration the close spacing between swirler elements leads to strong interaction that affects whether a CRZ forms, and pilot recess and counter-swirl helps to isolate swirlers from one another. Dynamics results focus on features identified near 500-Hz.

aircraft combustors

Flow Structure Comparison for Two 7-Point LDI Configurations

This paper presents a comparison primarily of the cold flow 2-D velocity profiles; and describes flame tube combusting flow operability for a 7-point Lean Direct Injector (LDI). This circular LDI array consists of a center element surrounded by six outer elements spaced 60 degrees apart; the spacing between all adjacent elements is the same. Each element consists of a simplex atomizer that injects at the throat of a converging-diverging venturi, and an axial swirler upstream of the venturi throat to generate swirl. The two configurations were: 1) one which consists of all 60 deg co-swirling axial air swirlers, and; 2) one configuration which uses a 60 deg swirler in the center, surrounded by counter-swirling 45 deg swirlers. Testing was done at 5- bar and at an inlet temperature of 700K. Two air reference velocities were considered in the cold flow measurements. The 2D velocity profiles were determined using particle image velocimetry. Results indicate the configuration using all 60 deg swirlers generates a field that moderates to a more uniform distribution at a shorter distance downstream and is more easily operable than the second configuration, which produces recirculation regions at the edges of the outer 45 deg swirlers, and results in a more stratified velocity field at any given axial location.

velocity

A Comparison of Combustion Dynamics for Multiple 7-Point Lean Direct Injection Combustor Configurations

The combustion dynamics of two 7-point lean direct injection (LDI) combustor configurations are compared. This 7-point LDI configuration has a circular cross section, with a center ("pilot") fuel-air mixer surrounded by six outer ("main") fuel-air mixers. Each fuel-air mixer consists of an axial air swirler followed by a converging-diverging venturi. A simplex fuel injector is inserted through the center of the air swirler, with the fuel injector tip located near the venturi throat. All 7 fuel-air mixers are identical except for the swirler blade angle. In the 'all-60' configuration, the swirler blade angle was 60 deg for all fuel-air mixers. In the '45-60' configuration, the swirler blade angle was 60 deg on the center and 45 deg on the outer fuel-air mixers. Testing was done in a 5-atm flame tube with inlet air temperatures from 630 to 830 F and equivalence ratios from 0.2 to 0.7. Combustion dynamics were measured using a cooled PCB pressure transducer flush-mounted in the wall of the combustor test section. Both configurations had large pressure fluctuations (greater than 2 psi peak-peak) near 730 Hz, the quarter-wave frequency. The all-60 configuration also had large pressure fluctuations near 1170 Hz; the 45-60 configuration did not. The 45-60 configuration had large pressure fluctuations near 480 Hz; the all-60 configuration did not.

combustion dynamics

Flow Structure Comparison for Two 7-Point LDI Configurations

This paper presents a comparison primarily of the 2-D velocity profiles in the non-burning system; and for the luminescent flame structure for a 7-point Lean Direct Injector (LDI). This circular LDI array consists of a center element surrounded by six outer elements spaced 60 degrees apart; the spacing between all adjacent elements is the same. Each element consists of simplex atomizer that injects at the throat of a converging-diverging venturi, and an axial swirler upstream of the venturi throat to generate swirl. The two configurations were: 1) one which consists of all 60 co-swirling axial air swirlers, and; 2) one configuration which uses a 60 swirler in the center, surrounded by counter-swirling 45 swirlers. Testing was done at 5 atm and an inlet temperature of 800F. Two air reference velocities were considered in the cold flow measurements and one common air flow condition for the burning case.The 2D velocity profiles were determined using particle image velocimetry and the flame structure was determined using high speed photography.

velocity

A Comparison of Three Second-generation Swirl-Venturi Lean Direct Injection Combustor Concepts

Three variations of a low emissions aircraft gas turbine engine combustion concept were developed and tested. The concept is a second generation swirl-venturi lean direct injection (SV-LDI) concept. LDI is a lean-burn combustion concept in which the fuel is injected directly into the flame zone. All three variations were based on the baseline 9- point SV-LDI configuration reported previously. The three second generation SV-LDI variations are called the 5-recess configuration, the flat dome configuration, and the 9- recess configuration. These three configurations were tested in a NASA Glenn Research Center medium pressure flametube. All three second generation variations had better low power operability than the baseline 9-point configuration. All three configurations had low NO(sub x) emissions, with the 5-recess configuration generally having slightly lower NO(x) than the flat dome or 9-recess configurations. Due to the limitations of the flametube that prevented testing at pressures above 20 atm, correlation equations were developed for the at dome and 9-recess configurations so that the landing-takeoff NO(sub x) emissions could be estimated. The flat dome and 9-recess landing-takeoff NO(x) emissions are estimated to be 81-88% below the CAEP/6 standards, exceeding the project goal of 75% reduction.

combustor

Investigations of Multiple Swirl-Venturi Fuel Injector Concepts: Recent Experimental Optical Measurement Results for 1-Point, 7-Point, and 9-Point Configurations

This paper presents results obtained during testing in optically-accessible, JP8-fueled, flame tube combustors using swirl-venturi lean direct injection (LDI) research hardware. The baseline LDI geometry has 9 fuel/air mixers arranged in a 3 x 3 array within a square chamber. 2-D results from this 9-element array are compared to results obtained in a cylindrical combustor using a 7-element array and a single element. In each case, the baseline element size remains the same. The effect of air swirler angle, and element arrangement on the presence of a central recirculation zone are presented. Only the highest swirl number air swirler produced a central recirculation zone for the single element swirl-venturi LDI and the 9-element LDI, but that same swirler did not produce a central recirculation zone for the 7-element LDI, possibly because of strong interactions due to element spacing within the array.

gas turbine combustion

Fundamental Study of a Single Point Lean Direct Injector. Part I: Effect of Air Swirler Angle and Injector Tip Location on Spray Characteristics

Lean direct injection (LDI) is a combustion concept to reduce oxides of nitrogen (NOx) for next generation aircraft gas turbine engines. These newer engines have cycles that increase fuel efficiency through increased operating pressures, which increase combustor inlet temperatures. NOx formation rates increase with higher temperatures; the LDI strategy avoids high temperature by staying fuel lean and away from stoichiometric burning. Thus, LDI relies on rapid and uniform fuel/air mixing. To understand this mixing process, a series of fundamental experiments are underway in the Combustion and Dynamics Facility at NASA Glenn Research Center. This first set of experiments examines cold flow (non-combusting) mixing using air and water. Using laser diagnostics, the effects of air swirler angle and injector tip location on the spray distribution, recirculation zone, and droplet size distribution are examined. Of the three swirler angles examined, 60 degrees is determined to have the most even spray distribution. The injector tip location primarily shifts the flow without changing the structure, unless the flow includes a recirculation zone. When a recirculation zone is present, minimum axial velocity decreases as the injector tip moves downstream towards the venturi exit; also the droplets become more uniform in size and angular distribution.

vortex

Fundamental Study of a Single Point Lean Direct Injector. Part I: Effect of Air Swirler Angle and Injector Tip Location on Spray Characteristics

Lean direct injection (LDI) is a combustion concept to reduce oxides of nitrogen (NOx) for next generation aircraft gas turbine engines. These newer engines have cycles that increase fuel efficiency through increased operating pressures, which increase combustor inlet temperatures. NOx formation rates increase with higher temperatures; the LDI strategy avoids high temperature by staying fuel lean and away from stoichiometric burning. Thus, LDI relies on rapid and uniform fuel/air mixing. To understand this mixing process, a series of fundamental experiments are underway in the Combustion and Dynamics Facility at NASA Glenn Research Center. This first set of experiments examines cold flow (non-combusting) mixing using air and water. Using laser diagnostics, the effects of air swirler angle and injector tip location on the spray distribution, recirculation zone, and droplet size distribution are examined. Of the three swirler angles examined, 60 deg is determined to have the most even spray distribution. The injector tip location primarily shifts the flow without changing the structure, unless the flow includes a recirculation zone. When a recirculation zone is present, minimum axial velocity decreases as the injector tip moves downstream towards the venturi exit; also the droplets become more uniform in size and angular distribution.