NASA NTRS · 20205004139
HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report
Abstract
The purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test was a follow-on to the original Radiation Lot-Specific Acceptance Testing (RLAT) performed on this LDC. Application-specific load currents were used for the line regulation and load regulation measurements. All other parameters were measured with standard bias conditions as specified in the datasheet.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Megan Casey, Anthony Phan, Alyson Topper. 2020-04-30. HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report. https://ntrs.nasa.gov/citations/20205004139
Cite the original work for its findings. Save a collection to share your selection of sources.