NASA NTRS · 20205011830

Fitting Leak Test Report

Abstract

Many Human Landing System flight elements are anticipated to implement mechanically connected joints in cryogenic fluid lines to simplify system assembly. These joints will need to survive launch vibration, while cold, and remain as leak‐free as possible to minimize commodity loss. Threaded fluid fittings should be qualified for use in their expected environments to reduce risk and ensure mission success. A new ground‐based test apparatus was developed and validated to obtain quantifiable low leak rate test data for a small component, such as a pressurized threaded fluid fitting, while in the temperature range of liquid hydrogen. A cryocooler is used to attain the cold test temperature and helium leakage from a pressurized fitting mounted within a vacuum test chamber is measured using a mass spectrometer leak detector. Two different sizes of Swagelok VCR fittings with three different types of seal rings were selected as the test articles for the initial proof of concept testing. Each fitting configuration was subjected to two consecutive cryogenic thermal cycles and cold leak measurement tests, followed by exposure to a high vibration test profile at ambient temperature on a shaker table, and then two additional cold leak measurement tests. Very low leak rates, below the acceptable leak rate threshold, were measured at the pressures tested. Several enhancements to the test hardware are discussed that would facilitate a comprehensive fitting qualification test campaign by enabling a higher test throughput rate and ensuring a repeatable test profile.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jared Sass, Angela Krenn. 2020-12-28. Fitting Leak Test Report. https://ntrs.nasa.gov/citations/20205011830

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Validation & Verification of CFD Models for Cryogenic Fluid Management of Propellant Tanks in Space

This article describes the need and the strategy for CFD model development, validation, and verification for Cryogenic Fluid Management (CFM) of Propellant Tanks in Space. It describes the type of CFD models that must be developed to address the future needs of Space CFM. It also discusses the two classes of experiments currently used to validate the fidelity of the CFD models. These two experiment classes are: (a) the small-scale simulant fluid science experiments that are equipped with scientific diagnostics to elucidate the underlying two-phase fluid physics of the CFM processes; and (b) the large-scale cryogenic experiments that assess the engineering performance of the propellant tank for storage and transfer. The current status of the CFD model development and validation is briefly assessed by presenting examples of segregated two-phase flow problems that have been successfully modeled. The future model development directions for CFM situations involving more complex interpenetrating phases are also defined.

Cryogenic Fluid Management

Comparison of Liquefaction Testing with Liquid Nitrogen and Liquid Oxygen

Liquid nitrogen is often used as a substitute for oxygen testing due to safety concerns, and the general similarity between their fluid properties. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, an opportunity arose to compare liquid nitrogen and liquid oxygen behavior using the same test hardware in similar test conditions. Comparative testing would verify whether the system response to nitrogen and oxygen would behave in a similar manner. Tests that were investigated include system boil-off heat load determination, autogenous pressurization, cryocooler loop initiation, and cryocooler loop operations. Results from testing are shown and compared to verify that liquid nitrogen and liquid oxygen tests yield similar system responses, and that nitrogen can be used as a substitute for oxygen in developmental tests at cryogenic temperatures.

Cryogenic Fluid Management

Low Leakage Valves for Long Duration Missions

This paper presents a status update on the low leakage cryogenic test valves currently under development at NASA’s Marshall Space Flight Center. These valves consist of a 3-inch isolation valve, a 3-inch relief valve, and an 8-inch pre-valve. Each of these valves contain a self-aligning seat and poppet design to significantly reduce the quantity of propellant flowing past the seat when the valve is in its closed state (internal leakage). This self-aligning design utilizes a metallic poppet head with five degrees of freedom and is intended to allow a valve to be more tolerant of the imperfect contacts and misalignments that are commonly found between sealing surfaces. This paper covers the test articles, facilities, objectives, and preliminary results.

Cryogenic Fluid Management