Search NASA⌕ Search

NASA NTRS · 20220010052

Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing

Abstract

Maintaining molecular cleanliness during the JWST’s Optical Telescope/Instrument Module (OTIS) Cryogenic Thermal Vacuum (TV) test campaign was critical to the success of its optical mission on orbit. In the thermal vacuum tests leading up to the final cryogenic test to validate the OTIS flight hardware, NASA Johnson Space Center’s (JSC’s) TV Chamber A was fully characterized for molecular contamination. It was found to contain common volatile condensable materials (VCM), including hydrocarbons, plasticizers, and silicones, all of which absorb in JWST’s infrared wavelength region. Due to the risks involved, cleaning molecular contamination from the OTIS mirrors was not an option and heating the Primary Mirror (PM) segments would have also been a risky and expensive endeavor. As a result, a monitoring process was developed and implemented during four different Pathfinder or risk reduction tests that were scheduled to occur prior to the flight hardware test. The goal was to quantify and assess the risk of molecular contamination depositing on the PM resulting from relatively warm chamber shrouds “leading” colder PM mirrors during warmup, by a margin of 10-50 Kelvin (K). This was accomplished using Cryogenic Quartz Crystal Microbalances (CQCMs), held at temperatures slightly cooler than the segments to signal the onset of contamination events. Per the JWST Contamination Control Plan (CCP)1, the total Primary Mirror molecular allocation requirement was 50 angstroms. In all tests, the results showed an average accumulated molecular contamination of <10 angstroms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kelly A Henderson-Nelson, Michael Woronowicz, Joseph O Ward, Eve M Wooldridge, Carl Reis, Jesse Huguet, Keith Havey. Molecular Accumulation during JWST’s Optical Telescope Cryogenic Thermal Vacuum Testing. https://ntrs.nasa.gov/citations/20220010052

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Subtleties of nanophotonic lithium niobate waveguides for on-chip evanescent wave sensing

Thin-film lithium niobate (TFLN) is promising for optical sensing due to its high nonlinearities, but its material properties present unique design challenges. We compare the sensing performance of the fundamental modes on a TFLN waveguide with a fluorescent dye sample. The TM mode has better overlap with the sample, with a 1.4 × greater sample absorption rate versus the TE mode. However, the TM mode also scatters at a 1.4 × greater rate, yielding less fluorescence overall. The TE mode is, therefore, more appropriate for sensing. Our findings have important implications for TFLN-based sensor designs.

optics↗

Baseline Optical Design for an Integrated Radio and Optical Communication System

This document outlines the baseline optical design for an Integrated Radio and Optical communication (iROC) system, specifically the version labeled in-house as Lunar R1.2a. The version number corresponds to the particular design iteration, including major and minor changes that have been made throughout the design process. The catadioptric design is based on a reflective Cassegrain telescope configuration united with refractive tertiary components in order to approach a diffraction limited, laser beam expander communication transmitter. The configuration presented is intended to be used as an optical transmitter only. Optical design parameters, far-field beam propagations, optical component sensitivity studies, and design explorations are included to provide a high-level understanding of the beam expander’s basic design requirements and optical performance.

optics↗