Mechanics of Preloaded Bolt Tensile Loading With Focus on Load Introduction Factor

Abstract

The bolt tensile and joint separation loads are directly influenced by the locations at which the external loads enter the clamped members of a preloaded bolted joint (PBJ) and the associated load-paths through the joint. This physical load introduction mechanism affecting the bolt tensile loading is typically represented in the bolt tensile load equation, in part, by a load introduction factor (LIF), which was shown by H.M. Lee of Marshall Spaceflight Center to be a natural product of the bolt tensile load equation using a linear spring stiffness model. This LIF, being a function of load-path stiffness, has subsequently been denoted as the stiffness-based LIF (SBLIF), providing a framework to calculate the LIF using whatever load-path stiffness approximations are appropriate. Expanding upon the work of Lee, it is shown that the SBLIF and the joint stiffness factor are functions of the stiffnesses of the same load-paths and regions within a PBJ, and thus they should not be treated as independent variables. Mathematical expressions for the SBLIF are presented. Comparisons are shown between the analytically calculated SBLIF, the analytically calculated geometric LIF (GLIF), which is a simple clamped-member thickness ratio, the experimentally derived LIF, and the LIF determined by finite element analysis (FEA). Using experiment and FEA as a benchmark, the SBLIF, using traditional load-path stiffness approximations, enables a more accurate prediction of bolt tensile loading than the GLIF, although it can be unconservative near joint separation. The GLIF generally attributes more of the externally applied tensile load to the bolt than does the SBLIF, potentially resulting in heavier and/or more costly bolted joints. Mathematical relationships between the SBLIF and the GLIF are developed. Supplemental material is provided in the appendixes where the historical practice of using the joint compressive stiffness in place of the joint tensile stiffness is evaluated. The appendixes include step-by-step examples demonstrating the calculation of the SBLIF using traditional stiffness approximations and conclude with the development of the joint diagram in terms of the SBLIF, culminating into formulas for the key features of a joint diagram, which is useful for programming.

Explore related subjects

Keep this discovery

BibTeXRIS

John K Ramsey. 2025-05-01. Mechanics of Preloaded Bolt Tensile Loading With Focus on Load Introduction Factor. https://ntrs.nasa.gov/citations/20250005284

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related discoveries

Development and Validation of a High-Vacuum Thermal Conductivity Testbed for Aerospace Interface Materials

Spacecraft thermal margins depend on the temperature penalty of installed interfaces, yet catalog conductivity omits bondline thickness, mating surfaces, preload, and environment. The Testbed for Advanced Interface Materials in Vacuum (TAIMV) addresses this engineering-data gap by converting ambient/vacuum temperature fields from a four-coupon stack into quantities usable in spacecraft thermal models. Its 17-node steady-state model resolves axial conduction, parasitic fixture paths, grease-filled contact, radiation, and ambient convection. Four monolithic checks gave axial heat-rate ratios of 0.90–1.02, and Braycote calibration self-recovery gave 2.20% casewise mean absolute percentage error (MAPE) and 2.85% maximum difference. With transferable fixture terms frozen, Krytox LVP tested cross-material transfer against a manufacturer-derived external relation. The six Krytox cases gave 2.28% MAPE, 5.10% maximum difference, and full-field residual root-mean-square values of 0.553 °C ambient and 1.306 °C vacuum. Installed-joint resistance spanned 6.39–7.15 × 10⁻⁴ m²·K/W for Braycote and 4.09–4.49 × 10⁻⁴ m²·K/W for Krytox, corresponding to 2.33–6.66 K per modeled interface over the tested heat-flux range. TAIMV therefore supplies directly usable installed-joint resistance and conductance, plus apparent installed conductivity and explicitly model-conditioned grease conductivity/contact terms.

heat transfer

Multiscale Modeling of Fracture Strength in Fibrous Thermal Protection System Materials

This work presents a multiscale modeling approach to predict the fracture strength of fibrous Thermal Protection System (TPS) materials. The model assumes that system failure is initiated at the joints between individual fibers. We investigated three distinct TPS compositions: amorphous silica, alumina and aluminosilicate fibers. Molecular dynamics (MD) simulations were employed to determine the fracture strength values of these fiber joints for both material systems. These fracture strength values were then integrated into simulations of 3D randomly populated fiber structures, where tensile load transfer occurs through the fiber joints. These microscale properties are upscaled through a renormalization approach [1] to predict macroscale tensile strength of 3D random fiber networks, accounting for joint-dominated failure and effective load-bearing area. The study concludes by demonstrating the resulting strength variation as a function of material composition, fiber density, and morphology. We also show validation of results by comparing them against explicit fiber finite element (FE) modeling [2] where fiber joint fracture is represented by cohesive elements.

Jaehyun Cho

Corrosion Resistance of Lignin-Based Thermoplastic Adhesive-Bonded Aluminum Joints

Adhesive-bonded joints are essential for lightweight, multimaterial automotive structures. We developed a lignin-based thermoplastic adhesive with adhesion strength comparable to conventional epoxy adhesives (20–23 MPa), while offering exceptional durability, recyclability, and corrosion resistance. Unlike commercial epoxy adhesives requiring refrigerated storage, our adhesive retains its bonding potential after a year of ambient conditioning. Bonded joints can be repeatedly disassembled and rejoined with less than 2% strength loss. After 500 h of salt fog exposure, the adhesive-bonded aluminum joints exhibited a 24% strength reduction, compared to 61% reduction in strength of joints based on a commercial epoxy adhesive.

Yu, Zeyang [ORNL] (ORCID:0000000209002374)