Search NASA⌕ Search

DOE OSTI · 1000178

Validation of Statistical Sampling Algorithms in Visual Sample Plan (VSP): Summary Report

Abstract

The U.S. Department of Homeland Security, Office of Technology Development (OTD) contracted with a set of U.S. Department of Energy national laboratories, including the Pacific Northwest National Laboratory (PNNL), to write a Remediation Guidance for Major Airports After a Chemical Attack. The report identifies key activities and issues that should be considered by a typical major airport following an incident involving release of a toxic chemical agent. Four experimental tasks were identified that would require further research in order to supplement the Remediation Guidance. One of the tasks, Task 4, OTD Chemical Remediation Statistical Sampling Design Validation, dealt with statistical sampling algorithm validation. This report documents the results of the sampling design validation conducted for Task 4. In 2005, the Government Accountability Office (GAO) performed a review of the past U.S. responses to Anthrax terrorist cases. Part of the motivation for this PNNL report was a major GAO finding that there was a lack of validated sampling strategies in the U.S. response to Anthrax cases. The report (GAO 2005) recommended that probability-based methods be used for sampling design in order to address confidence in the results, particularly when all sample results showed no remaining contamination. The GAO also expressed a desire that the methods be validated, which is the main purpose of this PNNL report. The objective of this study was to validate probability-based statistical sampling designs and the algorithms pertinent to within-building sampling that allow the user to prescribe or evaluate confidence levels of conclusions based on data collected as guided by the statistical sampling designs. Specifically, the designs found in the Visual Sample Plan (VSP) software were evaluated. VSP was used to calculate the number of samples and the sample location for a variety of sampling plans applied to an actual release site. Most of the sampling designs validated are probability based, meaning samples are located randomly (or on a randomly placed grid) so no bias enters into the placement of samples, and the number of samples is calculated such that IF the amount and spatial extent of contamination exceeds levels of concern, at least one of the samples would be taken from a contaminated area, at least X% of the time. Hence, "validation" of the statistical sampling algorithms is defined herein to mean ensuring that the "X%" (confidence) is actually met.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nuffer, Lisa L, Sego, Landon H, Wilson, John E, Hassig, Nancy L, Pulsipher, Brent A, Matzke, Brett D. 2009-02-18. Validation of Statistical Sampling Algorithms in Visual Sample Plan (VSP): Summary Report. https://doi.org/10.2172/1000178

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Morgana Overview – NCERC Support for Dynamic Subcritical Experiments

The LANL Subcritical Experiments Program (SCE) recently executed the Morgana Subcritical Experiment at the NNSS. This was the first subcritical experiment executed by LANL for several years (since 2021). It was also notably the first that required SCE personnel to have FMH qualifications for a portion of the work conducted under nuclear criticality safety limits.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

AWSD Reactive Burn Model for the HMX‐Based High Explosive LX‐04

An Arrhenius–Wescott–Stewart–Davis (AWSD) reactive burn model is applied to describe shock initiation and detonation properties of the HMX-based high explosive LX-04. The parameters in the model are calibrated to data from multiple sources. The thermodynamic equations of state used in the model are calibrated to a combination of thermochemical calculations for HMX and LX-04 as well as experimentally-measured cylinder expansion results for LX-04. The kinetic parameters are calibrated to velocity data from gas gun experiments performed using EDC-32—a high explosive with the same chemical composition as LX-04 but different structural properties, and scaled rate stick data for PBX 9012. The AWSD model is shown to accurately describe the shock initiation and propagation of LX-04. Very good agreement is observed between the available experimental data and the AWSD model output. The presented results constitute an accurate LX-04 reactive burn model for use in engineering-scale models and simulations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Surface and Buried Thermal, and RGB Unexploded Ordnance Data Collection

This document provides a description of a data collection campaign of unexploded ordnance (UXOI) set. The dataset captures a controlled UAV imaging campaign designed to support detection of UXO across varied environmental conditions. Data were collected during three campaigns in Norris and Northeast Knoxville, Tennessee, using RGB, and thermal sensors mounted on Parrot UKR. In total, the dataset contains 9925 images, 26 full-motion video, and approximately 81.99 GB of data, collected across late spring/summer conditions, every hour during sunlight, and multiple surface contexts, including tall grass, short grass, gravel, as well as buried in sand, and other gravel mixtures. The collection was designed to capture thermal and visual variability relevant to UXO detection in agricultural land, bare earth, and subsurface. Review of the imagery showed that ordnance was most detectable during periods of changing solar input, especially approximately 10-60 minutes after sunrise, approximately 20-60 minutes after sunset, and 2-3 min after cloud cover interrupted prolonged solar heating. These conditions increased thermal contrast because many ordnance items retained or released heat differently than the surrounding vegetation and ground surface. This dataset provides a useful resource for developing and evaluating airborne UXO detection methods under realistic field conditions. All ordnance used in the study was inert, and thermal behavior may differ from that of live ordnance. In addition, variation in ordnance type, composition, and placement introduced differences in thermal response that should be considered when interpreting results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗