Search NASA⌕ Search

DOE OSTI · 1023813

Candidate Structural Materials for In-Core VHTR Application

Abstract

Graphite moderated gas cooled reactors led the way into the nuclear age with the Chicago Pile-1 reactor, which provided the first sustained critical reaction in December, 1942. The first commercial nuclear plant, Calder Hall in the UK, went critical in 1956 with an outlet gas temperature of {approx}345 C. As depicted in Fig. 1, in five decades since Calder Hall, outlet temperature increased rapidly, reaching a plateau of {approx}950 C. This apparent ceiling is in large part due to limitations in the structural materials utilized within the core (e.g. control systems) and primary loop (hot duct, heat-exchangers etc.) Simply, the operating temperatures of Generation III (HTGR's) are very near performance limits of the structural alloys used, both in terms of elevated temperature and as-irradiated properties. This limitation remains today and is the reason the outlet temperature of the Generation IV Very High Temperature Reactor (VHTR) continues to be revised downward from the original optimistic goal of {approx}1200 C, to it's current target outlet temperature of {approx}950 C, a temperature consistent with the previous generation of HTGR's. An example of the challenges facing Generation IV VHTR is found by considering the control rods. For the Fort St. Vrain Reactor the control system consisted of thirty tubes each containing B4C control material. Alloy 800, originally developed by Inco in the 1950's under the trade-name Incoloy 800 and 800H had found widespread application is steam generators, turbines and was selected for this control rod application. These materials are included for Class 1 Nuclear Component by ASME section III. In addition to Ft. St Vrain, alloy 800H has found control rod application in the German HTR and Japanese HTTR reactors and is the primary choice Pebble Bed Modular Reactor (a HTGR) reactivity control system. Figure 2 gives the ASME allowed stress for Alloy 800H. Due to the loss in creep rupture strength, the allowed design stress for decreases substantially above {approx}500 C. For the operating temperature (and current maximum code temperature) of the Fort St. Vrain reactor ({approx}760 C) the control rod designed from Alloy 800H would be allowed approximately 20 MPa primary stress. For the anticipated temperature of the VHTR that stress would likely be under 10 MPa in the non-irradiated condition. Selection of VHTR in-core structural material will depend on the ability for the material to withstand extreme temperatures and irradiation. The use of Alloy 800H for control rod applications is preferred, but will require designing with a relatively low strength material which becomes brittle upon modest irradiaton. Presently, more fidelity in both design and the available Alloy 800H database are required to judge the lifetime this alloy will have in service. The only currently envisioned alternative to Alloy 800H are the CFC and SiC/SiC composites, which are currently challenged by code qualification issues. As with Alloy 800H, the composite irradiation data-base is inadequate, though it appears that the CFC service lifetime will be limited due to its anisotropic dimensional change under irradiation to doses somewhat higher than Alloy 800H (1-5 x 10{sup 25} n/m{sup 2}), while SiC/SiC composites appear to retain their mechanical properties to doses in excess of the VHTR lifetime dose. As the path to qualification of both CFC and SiC/SiC are similar, it appears that SiC/SiC is more attractive for high-dose Gen IV application unless high thermal conduction is required.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Snead, Lance Lewis, Katoh, Yutai, Windes, Will, Smit, Kobus. 2008-01-01. Candidate Structural Materials for In-Core VHTR Application. https://searchnasa.com/record/osti%3A1023813/candidate-structural-materials-for-in-core-vhtr-application

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗