DOE OSTI · 1045802
Multi Optical Transition Radiation System for ATF2
Abstract
In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and emittances coming from the ATF Damping Ring. With an optical resolution of about 2 {micro}m an original OTR design (OTR1X) located after the septum at the entrance of the EXT line demonstrated the ability to measure a 5.5 {micro}m beam size in one beam pulse and to take many fast measurements. This gives the OTR the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter. Furthermore the nearby wire scanners will be a definitive test of the OTR as a beam emittance diagnostic device. The multi-OTR system design proposed here is based on the existing OTR1X.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Alabau-Gonzalvo, Javier, Blanch Gutierrez, Cesar, Civera, Jose Vicente, Faus-Golfe, Angeles, Garcia-Garrigos, Juan, Cruz, Juan, McCormick, Douglas, White, Glen. 2012-07-13. Multi Optical Transition Radiation System for ATF2. https://searchnasa.com/record/osti%3A1045802/multi-optical-transition-radiation-system-for-atf2
Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.