DOE OSTI · 1048123
SRF Cavity Surface Topography Characterization Using Replica Techniques
Abstract
To better understand the roll of topography on SRF cavity performance, we seek to obtain detailed topographic information from the curved practical cavity surfaces. Replicas taken from a cavity interior surface provide internal surface molds for fine Atomic Force Microscopy (AFM) and stylus profilometry. In this study, we confirm the replica resolution both on surface local defects such as grain boundary and etching pits and compare the surface uniform roughness with the aid of Power Spectral Density (PSD) where we can statistically obtain roughness parameters at different scales. A series of sampling locations are at the same magnetic field chosen at the same latitude on a single cell cavity to confirm the uniformity. Another series of sampling locations at different magnetic field amplitudes are chosen for this replica on the same cavity for later power loss calculation. We also show that application of the replica followed by rinsing does not adversely affect the cavity performance.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
2012-07-01. SRF Cavity Surface Topography Characterization Using Replica Techniques. https://www.osti.gov/biblio/1048123
Cite the original work for its findings. Save a collection to share your selection of sources.