DOE OSTI · 1059482
HLW Melter Control Strategy Without Visual Feedback
Abstract
Plans for the treatment of high level waste (HL W) at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) are based upon the inventory of the tank wastes, the anticipated performance of the pretreatment processes, and current understanding of the capability of the borosilicate glass waste form. The WTP HLW melter design, unlike earlier DOE melter designs, incorporates an active glass bubbler system. The bubblers create active glass pool convection and thereby improve heat and mass transfer and increase glass melting rates. The WTP HLW melter has a glass surface area of 3.75 m 2 and depth of ~ 1.1 m. The two melters in the HLW facility together are designed to produce up to 7.5 MT of glass per day at 100% availability. Further increases in HL W waste processing rates can potentially be achieved by increasing the melter operating temperature above 1150°C and by increasing the waste loading in the glass product. Increasing the waste loading also has the added benefit of decreasing the number of canisters for storage.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Matlack, Keith S., Kot, Wing K., Abramowitz, Howard, Callow, Richard A., Brandys, Marek, Joseph, Innocent, Pegg, Ian L., Kruger, A. A.. 2012-10-19. HLW Melter Control Strategy Without Visual Feedback. https://doi.org/10.2172/1059482
Cite the original work for its findings. Save a collection to share your selection of sources.