DOE OSTI · 1221575
Development of a Multi-Point Microwave Interferometry (MPMI) Method
Abstract
A multi-point microwave interferometer (MPMI) concept was developed for non-invasively tracking a shock, reaction, or detonation front in energetic media. Initially, a single-point, heterodyne microwave interferometry capability was established. The design, construction, and verification of the single-point interferometer provided a knowledge base for the creation of the MPMI concept. The MPMI concept uses an electro-optic (EO) crystal to impart a time-varying phase lag onto a laser at the microwave frequency. Polarization optics converts this phase lag into an amplitude modulation, which is analyzed in a heterodyne interferometer to detect Doppler shifts in the microwave frequency. A version of the MPMI was constructed to experimentally measure the frequency of a microwave source through the EO modulation of a laser. The successful extraction of the microwave frequency proved the underlying physical concept of the MPMI design, and highlighted the challenges associated with the longer microwave wavelength. The frequency measurements made with the current equipment contained too much uncertainty for an accurate velocity measurement. Potential alterations to the current construction are presented to improve the quality of the measured signal and enable multiple accurate velocity measurements.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Specht, Paul Elliott, Cooper, Marcia A., Jilek, Brook Anton. 2015-09-01. Development of a Multi-Point Microwave Interferometry (MPMI) Method. https://doi.org/10.2172/1221575
Cite the original work for its findings. Save a collection to share your selection of sources.