DOE OSTI · 1441287
Supo Thermal Model Development III
Abstract
This report describes the continuation of the Computational Fluid Dynamics (CFD) model of the Supo cooling system described in the reports, Supo Thermal Model Development 1 and Supo Thermal Model Development II 2 . The goal for this report is to more accurately estimate the natural convection heat transfer coefficient (HTC) of the system using the CFD results and to compare those results to remaining past operational data.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Wass, Alexander Joseph. 2018-06-11. Supo Thermal Model Development III. https://doi.org/10.2172/1441287
Cite the original work for its findings. Save a collection to share your selection of sources.