DOE OSTI · 1569726
Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer
Abstract
The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the electron beam energy. Axis-1 of DARHT produces a 20 MeV, 2 kA, 80-ns-FWHM electron beam. Electronic measurement with cell-voltage monitors which consists of a 75 ohm load resistor and a current viewing resistor (CVR) that are coupled together and injector capacitive monitors (EVACSUM) are summed to give the total beam energy at the output of the accelerator. Calibration of these monitors was last done in 1999 and is needed. Using the Compact electron Permanent Magnet Spectrometer (CePMSpec), we have developed a technique for measuring and adjusting the calibration of the accelerator cell load resistor/CVR by using the total energy of the beam. Each pair of cells is driven by pulsed power Blumleins, and each Blumlein is charged by a Blumlein Charge Unit (BCU). There are 64 cells and 32 Blumleins and BCUs. This technique is applied to all 32 BCUs.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Moir, David C., Burris-Mog, Trevor John, McCuistian, Brian Trent. 2019-10-08. Linear Induction Accelerator Cell Voltage Calibration Using Compact Electron Permanent Magnet Spectrometer. https://doi.org/10.2172/1569726
Cite the original work for its findings. Save a collection to share your selection of sources.