DOE OSTI · 1615652
Target Optimization Study: Tolerance Sensitivity
Abstract
A Work Package was initiated to investigate the potential for target optimization. The current design is made up of 82 disks 0.5 mm thick spaced 0.25 mm apart for helium coolant flow. This disk thickness and gap width are a result of continual increases is beam power and hence volumetric heating rate. Thickening the disks would mean higher disk temperatures, but this would be weighed against the prospect of fewer, thicker disks and wider coolant gap spaces, and the relaxed tolerances that would result. Fabrication of the target holder would be easier and less expensive, and target assembly would also be easier.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Olivas, Eric Richard, Mocko, Michael Jeffrey, Woloshun, Keith Albert. 2020-04-14. Target Optimization Study: Tolerance Sensitivity. https://doi.org/10.2172/1615652