DARHT Axis 1 Time-Resolved Injector Energy Measurement

Abstract

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Moir, David C., Burris-Mog, Trevor J., Jaworski, Michael Andrew, Mccuistian, Brian Trent. 2020-08-03. DARHT Axis 1 Time-Resolved Injector Energy Measurement. https://doi.org/10.2172/1645060

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

High Multiplicity Trigger for long-lived particles in CMS detector

Searches for long-lived particles (LLPs) at the CMS experiment often involve unconventional event topologies that are difficult to efficiently select using standard trigger strategies. To improve sensitivity to such signatures during LHC Run 3 operation, a dedicated High Multiplicity Trigger (HMT) has been developed and deployed in the CMS trigger system. The trigger targets events containing unusually large numbers of hits in the CMS cathode strip chamber (CSC) muon detectors, a characteristic signature of several LLP scenarios involving displaced decays in the muon system. The HMT implementation, trigger logic, rate dependence with pileup, and operational stability are described. Optimized hit multiplicity thresholds are used to maintain acceptable trigger rates under high-luminosity and high-pileup conditions while preserving high efficiency across a broad range of LLP lifetimes and kinematic regimes. The trigger performance is evaluated using both simulated event samples and proton-proton collision data collected during Run 3 of the LHC. The HMT substantially extends the CMS sensitivity to non-standard signatures associated with LLP decays and provides a flexible platform for future searches for physics beyond the Standard Model.

47 OTHER INSTRUMENTATION↗