Search NASA⌕ Search

SEARCH · Search NASA

Results for “DARHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

DARHT : Enduring Lessons from a Technical Project in a National Laboratory Context [Slides]

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory (LANL) is the world’s first flash x-ray facility able to take multiple high-resolution radiographs of the interior features of fast-moving dense objects during a single experiment. DARHT’s radiography and complimentary diagnostics makes it an important diagnostic tool in support of the US Department of Energy’s (DOE)/National Nuclear Security Administration (NNSA)’s stewardship of the US nuclear deterrent. The project to construct DARHT ran from 1988 through 2003. Initial Operating Capability along a single axis began in 1999. A technical issue delayed Critical Decision 4 for the full dual-axis capability until 2008. DARHT was characterized by several directed changes resulting from an environmental impact study, changes to the global security context resulting from the end of underground nuclear testing, and rapid evolution of applicable technology. Conventional building and lab-space construction were part of the project, but the project was dominated by Special Facility Equipment that, together with the mission to support the nuclear weapons program, required the project to be completed by national laboratories. Although the project pre-dated implementation of DOE Order 413.3, several important lessons for national laboratory projects remain applicable today and will be discussed here, including projects appropriate for the national laboratory environment, scope stability, risk acceptance and mitigation, communication, and collaboration. Finally, considerations for DOE contractor project managers are offered based upon the DARHT experience.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multidisciplinary Research and Development at the Dual-Axis Radiograph Hydrodynamic Test Facility (DARHT) [Slides]

DARHT is the nation’s premiere flash radiography facility. Flash radiography allows interior views of complex structures that are rapidly moving. DARHT is used to image the implosion of mock weapon assemblies containing surrogate materials. DARHT is the only dual-axis facility in the nation enabling 3D reconstructions, with multi-pulse capability for multiple time points. DARHT is an essential facility for Science-based Stockpile Stewardship at LANL and within the NNSA complex.

43 PARTICLE ACCELERATORS↗

2024 Results for Avian Monitoring at the Technical Area 36 Minie Site, Technical Area 39 Point 6, Technical Area 16 Burn Ground, and DARHT at Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) biological subject matter experts in the Environmental Protection and Compliance Division initiated a multi-year program in 2013 to monitor avifauna (birds) at two open detonation sites and one open burn site on LANL property. Additional monitoring began in 2017 at a third firing site, the Dual-Axis Radiographic Hydrodynamic Test (DARHT) Facility. In this annual report, we compare monitoring results from these efforts among years to identify and evaluate firing and open burn site impacts on the local bird community. The objectives of this study are • to determine whether LANL operations impact bird abundance, species richness, or diversity; • to examine occupancy and nest success of secondary-cavity nesting birds that use nest boxes; and • to examine chemical concentrations (such as radionuclides, inorganic elements, and/or organic compounds) in nonviable eggs and deceased nestlings that are collected opportunistically with the upper-level bounds of background concentrations, when available. During May through July 2024, LANL biologists completed multiple avian point count surveys at each of the following treatment sites: • Technical Area (TA) 36 Minie Site, • TA-39 Point 6, • TA-16 Burn Ground, and • DARHT. We recorded a total of 1,088 birds that represented 65 species at the four treatment sites and compared these results with data from their associated control sites. In 2024, abundance and species richness at treatment and control sites continued to trend similarly from year to year, with minor random deviations expected from bird communities. Species richness at firing sites differed little from the previous year’s values. Two new bird species were observed at the firing sites—cedar waxwing (Bombycilla cedrorum) and pinyon jay (Gymnorhinus cyanocephalus). Shannon diversity values at TA-36 Minie Site, TA-39, and DARHT were statistically higher than one or more of their associated controls. Annual species diversity at treatment sites was high in 2024 across all firing sites relative to similar habitat control sites. We also monitored avian nest boxes to compare occupancy and nest success data from nest boxes at treatment sites with the overall avian nest box monitoring network and against a subset of relevant control sites. Nest box success has decreased at both treatment and control sites since monitoring began, suggesting that overlapping climatic factors are responsible for patterns of declining nest success. In 2024, nonviable avian eggs and one nestling were opportunistically collected at Bandelier National Monument, TA-16 Burn Ground, TA-36 Minie, TA-39 Point 6, and DARHT. All egg samples and the one nestling sample were evaluated for per- and polyfluoroalkyl substances, which were detected from all locations, including the control site at Bandelier National Monument. Overall results from 2024 continue to suggest that operations at the four treatment sites are not negatively impacting bird populations. This long-term project will continue to monitor for any changes over time.

54 ENVIRONMENTAL SCIENCES↗

DARHT Axis 1 Performance Results with and without a Blumlein Charge Unit

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis 1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. As DARHT Axis 1 enters its twentieth year of operation, the probability of Blumlein Charge Unit (BCU) failure has increased and the risk of a failure on the day of an explosive experiment has become more likely. Replacement time for a BCU is four to six hours. This report examines the radiographic and beam transport effect of operating the accelerator with a missing or reduced charge voltage BCU. The results are compared with normal, full machine operation. A prescription for alternate operation with missing or reduced charge voltage on BCU22 is given.

47 OTHER INSTRUMENTATION↗

Optimization of DARHT Axis 1 Injector Voltage

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces a 20- MeV, 2-kA, 80-ns-FWHM electron beam. The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injector electron beam energy. The technique for time resolved measurement of the electron beam energy using electron Permanent Magnet Spectrometer (ePMSpec) has been developed. The electron energy then is used to infer the voltage produced by the injector pulsed power. The injector pulsed power of DARHT I consists of a 1.5-MV, glycol-insulated Blumlein that is pulsecharged by a step-up transformer and switched by four, laser-triggered spark gaps. A series of increasing impedance transmission lines are used to transform the output voltage of the Blumlein to a maximum of 3.8MV at the diode. Figure 1a shows a graphic of the Axis-1 prime power tank, Blumlein and downstream transmission lines. The injector pulse power is designed to produce voltage on a velvet cathode located in the vacuum vessel. The specifications of the voltage-pulse flat-top over 60ns is +/-1%. A key element in the high-voltage circuit is the ethylene glycol Blumlein. The outer volume, adjacent to the laser triggered switches of the Blumlein, is a peaking capacitor. This is an independent volume that contains a mixture of ethylene glycol and water to make it an adjustable capacitor of 380 to 750 pF.

43 PARTICLE ACCELERATORS↗

DARHT Axis 1 Bremsstrahlung Dose Measurements

he Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography ca pabilities using two electron Linear Induction Accelerators (LIA’s). Axis-1 of DARHT produces, nominally, a 20-MeV, 1.5-kA, 80-ns-Full Width at Half Max (FWHM) electron beam. The elec tron beam is focused on to a tantalum target to produce a Bremsstrahlung x-ray dose for flash radiography of dynamic systems. This paper will describe and compare a variety of techniques for determining the x-ray dose for two different beam currents produced by a 55mm and 70mm diameter cathode. The data was taken in November of 2022 on DARHT Axis 1. The experimen tal measurement techniques include a platinum calorimeter, a diamond radiation detector (DRD), and a Compton diode (CD). Gafchromic EBT3 self-developing dosimetry film was also used, but no useful results were obtained. Beam charge and energy were recorded and dose was calculated with this information using xtr with Dosecalcx, and simple dose charge-energy scaling. In this pa per, we will discuss the target geometry and experimental layout, the methods of measuring dose, dose diagnostics and measurement of beam charge and energy, and the comparisons of data and calculations.

43 PARTICLE ACCELERATORS↗

Q-6 DARHT Weather Enclosure Project Upgrades Design Review

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility is adding a weather enclosure for the vessel area that will require the Detonation Science and Technology Group’s (Q-6) support for installing new cabling infrastructure to support capacitive discharge unit (CDU) firing operations and diagnostics. The requirement’s work scope is described in Q-6-TR-0034U*, Q-6 Support for the DARHT Weather Enclosure Upgrade Project, Customer Requirements Review (CRR).

42 ENGINEERING↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

Python catemis package for DARHT Axis-II Dispenser-Cathode Emissivity and Temperature Analysis

The catemis python package includes the analysis methods used in paper "DARHT Axis-II Dispenser-Cathode Emissivity and Temperature", which was presented at the 2021 Weapons Engineering Symposium and Journal (WESJ) hosted by Los Alamos National Laboratory. The paper (LA-UR-21-25647) and presentation (LA-UR-21-28231) report on a temperature and emissivity model that has been developed and applied to data from diagnostics used to measure the surface temperature of the DARHT Axis-II hot dispenser cathode over more than a decade of operation. The catemis package provides all the methods used in reporting these results along with the data files used to create the plots and tables in the paper. This includes methods for loading and processing FAR spectral pyrometer data along with methods for temperature calibration of cathode images.

Koglin, Jason↗

System Requirements Development for Assembly Alignment at DARHT

Lawrence Livermore National Laboratory conducts a few experiments at the DARHT facility at Los Alamos National Laboratory in New Mexico each year and in order to align to both X-ray beams for imaging, the experimental assembly must be adjusted to the correct spot. The current system to align the position of the assembly requires technicians to lift the assembly out with a crane and adjust the position. This process of lifting the assembly out, adjusting, and lowering back in can add additional hours and even days onto an already limited schedule, which can be very costly as well. The goal of this document is to develop system requirements and a concept of operations for a new system to position and adjust the experimental assembly within DARHT in order to save time and money.

42 ENGINEERING↗

Design of the New DARHT X-ray and Neutron Shielding and Measured Results

The DARHT Weather Enclosure (WE) project provided an excellent opportunity to redesign and rebuild some of DARHT systems without introducing interruptions to normal operations. Multiple improvements were made to the facility to improve data quality and operational reliability.

43 PARTICLE ACCELERATORS↗

DARHT Radiographic Analysis of Spatially Modulated Objects

This document describes some analysis methods that can be performed using the Kaleidoscope test object (KTO) in order to assess DARHT radiography performance. The goal of these methods is to provide a simple metric of radiographic performance to compare different system configurations at DARHT. Specifically, these methods can be used to assess the Tiffany configurations to determine relative radiographic performance. To demonstrate the methods, we show results analysis performed on the ‘Tiffany A’ shot conducted in July 2021.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Estimation of the DARHT Radiographic Spot Size from Spatially Modulated Images

We wrote a software routine to find local extrema and calculate the contrast in the image for each feature set. The input is a KTO image in the standard DARHT orientation, pre-processed by flat-fielding, dark frame subtraction and de-warping. Table 1 shows contrast results for five contemporaneous DARHT images of the KTO. For some very dense feature sets, contrast measurements are not possible due to a lack of local extrema, and in this case no contrast value is given in the table. Highlighted in bold are the contrast values for each image that bound the threshold C = 0.01. The contrast is varying rapidly enough with spatial frequency that we can interpolate between these values to find an estimate of the spatial frequency at the threshold value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resistive Wall Simulations for the DARHT Multi-Pulse Test Line

The multi-pulse test line (MPTL) presently under T development at the Dual Axis Radiography Hydrodynamic Test (DARHT) facility may have several meters of drifting beam transport without external magnetic focusing field. The absence of external magnetic focusing is the worst case for growth of the resistive-wall instability. This instability is usually considered to be strictly a long-pulse (low-frequency) problem, but has been theoretically shown to couple the multiple pulses in a long pulse train, such as are expected to be the subject of experimentation on the MPTL. In this note, we explore the resistive wall instability in the MPTL parameter range using our LAMDA beam dynamics code. (LAMDA stands for Linear Accelerator Model for DARHT)

43 PARTICLE ACCELERATORS↗

Diamagnetic Loop Testing on DARHT-I

Diamagnetic loops (DML) can be used as a noninvasive method for measurements of beam size in electron beam accelerators that use solenoidal magnetic transport. The loop fundamentally measures the magnetic flux excluded by a diamagnetic object. A comprehensive theory relates the rms beam radius to the excluded flux measured by the DML. We have built, and calibrated a DML apparatus. Recently, this DML has been used to measure the size of the electron beam near the final focus of the DARHT-I flash-radiography accelerator. Results are in agreement with beam transport code predictions. In this article, we review and summarize the construction, calibration, and electron-beam testing of this DML.

43 PARTICLE ACCELERATORS↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗