DOE OSTI · 1663164
Evaluation of the 2018 Version of the Integrated Surveillance Program Database Pressure Equation
Abstract
The Integrated Surveillance Program (ISP) Database Pressure Equation was developed to determine with reasonable certainty the total maximum pressure of hydrogen and other gases in packaged 3013 containers stored at Savannah River Site (SRS) in support of the destructive evaluation (DE) process. The pressure equation in the Department of Energy (DOE) 3013 Standard, “Standard for Stabilization, Packaging and Storage of Plutonium- Bearing Materials” (DOE-STD-3013-2004) used a bounding assumption that all the water is decomposed to form hydrogen. However, the results of Los Alamos National Laboratory (LANL) shelf-life experiments showed that hydrogen is consumed, and that the maximum pressures would not approach the design pressure of the 3013 container. Therefore, the ISP Database Pressure Equation was revised in 2008 to include terms for the generation of helium and hydrogen as a function of time, as well as the consumption of water and destruction of hydrogen based on shelf-life results. The 2008 ISP Database Pressure Equation provided a more reasonable estimate of the total maximum pressure in packaged 3013 containers than the pressure equation in versions of the 3013 Standard issued prior to 2018.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Narlesky, Joshua Edward, Veirs, Douglas Kirk, Cheadle, Jesse M.. 2020-09-18. Evaluation of the 2018 Version of the Integrated Surveillance Program Database Pressure Equation. https://doi.org/10.2172/1663164