This work presents one year results for a side-by-side comparison of 5 different bifacial technologies, deployed in a 75-kW single-axis tracked field at Golden, CO. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed for a direct technology comparison and calculation of bifacial gain. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. High accuracy string-level DC monitoring and module-level measurements are also presented, showing effects of snow and edge effects in the order of +/- 3% for non-uniform irradiance across the row. Data from a custom-module to measure shading loss from the torque-tube is installed, showing up to 6% irradiance non-uniformity for the month of January.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pelaez, Silvana Ayala (ORCID:000000030180728X), Deline, Chris (ORCID:0000000298678930), Marion, Bill (ORCID:0000000338456620), Sekulic, Bill, McDanold, Byron, Parker, Joshua, Monarch, Mark (ORCID:0000000260620709), Stein, Joshua S. (ORCID:0000000294221976). 2020-08-12. Ultimate Bifacial Showdown: 75kW Field Results. https://www.osti.gov/biblio/1669536