PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months.

array↗

Quantifying and Valuing Fundamental Characteristics and Benefits of Floating PV Systems

This project undertook the first systematic and comprehensive collection of Floating Photovoltaic (FPV) related techno-ecological data across diverse geographic regions of the United States. It examined FPV performance, assessed potential environmental risks and benefits, and provided data to support the development of research protocols for better understanding the impacts of FPV. As part of this process, we conducted a detailed study of four existing FPV sites and three land-based PV (LPV) sites in Florida and California.

14 SOLAR ENERGY↗

PV Lifetime Project (2024 NREL Annual Report)

DOE’s PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions.

14 SOLAR ENERGY↗

PV Modules Temperature Variation and Patterns in Medium and Utility-Scale Floating PV Systems

This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months. Index Terms - photovoltaic module, floating PV systems, string, array, temperature, mismatch, utility scale.

ENGINEERING,SOLAR ENERGY↗

PV Lifetime Project (2021 NREL Annual Report)

DOE's PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial performance loss rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field performance loss requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement. Current samples deployed and monitored in this way include Jinko Solar (2016), Trina Solar (2016), Hanwha Q-Cells (2017), Panasonic (2018), LG (2018), Canadian Solar (2018), Mission Solar (2019). More recently, modules from Sunpreme (2019), and LONGi (2020) have been deployed but not yet analyzed. Overall annual performance loss rates are as follows: our first modules to be deployed (Jinko and Trina) have annual median performance loss rate between -0.4%/yr and -0.9%/yr, mainly concentrated in the first year. The QCells mono-PERC and multi-PERC modules have an annual degradation rate of -0.76%/yr and -0.69%/yr respectively, also concentrated in the first year of operation. Panasonic and LG modules displayed negligible performance loss in the past two years, at 0.1%/yr and -0.0%/yr respectively. They also were the only modules with initial IV curve measurements consistently above the nameplate rating. Possibly relatedly, these are also the only two N-type silicon module types analyzed so far. Canadian Solar multi-PERC modules demonstrated a -1.3%/yr degradation rate which actually accelerated in the past year, so this will be a module type to monitor in future years. Mission Solar modules exhibited strong recoverable performance loss, consistent with LeTID susceptibility. (The same is true for the Jinko JKM260 module type). Annual performance loss actually showed improvement in time at +0.3%/yr after 2 years in the field, although the module initially was measured at 3% below nameplate rating. These modules could therefore be experiencing a form of post-LeTID recovery. Initial measurements have been conducted on the next two module types - Sunpreme n-HIT and LONGi bifacial mono-PERC. We will report on initial year-1 performance change for these modules in the next PV Lifetime annual report. For the remaining modules, an additional year of field exposure will provide greater certainty in annual degradation rates, particularly for those with degradation concentrated in the initial year of field deployment.

14 SOLAR ENERGY↗

Understanding Bifacial Photovoltaic's Potential

The performance of bifacial PV systems depends greatly on the installed conditions. Previous simulations and results have shown very high bifacial gain improvement, but this may not be the case for all conditions, particularly for large-scale systems with self-shading, lower-cost PV modules (PERC) which might have lower bifaciality coefficient, and field deployments over natural ground cover. But not to worry! Financial models indicate that even with these lower performance conditions, and with bifacial gain of 4%-7%, bifacial modules can still provide improved LCOE.

bifacial↗

Measuring and Modeling Bifacial Technologies

Measuring and modeling bifacial technologies is of interest for new system design, capacity testing, and performance evaluation. The bifacial PV field at NREL has been gathering data for different bifacial technologies and sensors for the last 2.5 years, making it possible to compare bifacial performance with monofacial counterparts, as well as experimental demonstrations of best locations to place sensors to match modeled and perceived irradiance non-uniformity on the rear of the bifacial modules. This presentation summarizes performance, degradation, sensor position for module edge effects and the impact of row edge effects, and the roadmap for NREL bifacial modeling tools.

bifacial PV↗

Silicon Heterojunction Field Performance

The market share of silicon heterojunction (SHJ) modules are expected to increase in the following years. The presentation discusses field performance of SHJ and compares it to other high-efficiency modules. In-depth materials characterization is used to understand the origins of degradation in these type of modules.

ENGINEERING,SOLAR ENERGY↗

High-Resolution Floating Solar PV Data

This dataset contains over two years of 1-minute resolution data collected from four floating solar sites, as well as data from a land-based PV system co-located with one of the floating sites. The dataset includes highly granular module temperature measurements - five modules per floating site, with three sensors per module, totaling 15 module temperature sensors per floating site. In addition to the module temperature data, meteorological data collected at the floating sites is also included, along with traditional PV system-level parameters. The data is intended for analysis of solar energy production, efficiency, and performance degradation over time. For information about the data file usage see the "README" resource below. See "Metadata File" for information about individual files and other metadata information.

Array↗

Field-Array Benchmark of Commercial Bifacial PV Technologies with Publicly Available Data

We present results for a 75-kW field array deployed with rows of 5 different commercially available bifacial technologies. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed in the 10-row field. High accuracy string-level DC monitoring and module-level measurements have been recorded for six months. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. A custom-module to measure shading loss from the torque-tube was installed. One month data shows up to 6% irradiance non-uniformity. A fixed-tilt test-site with 3 years of bifacial data is also presented, with a bifacial gain of 3%.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Ultimate Bifacial Showdown: 75kW Field Results

This work presents one year results for a side-by-side comparison of 5 different bifacial technologies, deployed in a 75-kW single-axis tracked field at Golden, CO. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed for a direct technology comparison and calculation of bifacial gain. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. High accuracy string-level DC monitoring and module-level measurements are also presented, showing effects of snow and edge effects in the order of +/- 3% for non-uniform irradiance across the row. Data from a custom-module to measure shading loss from the torque-tube is installed, showing up to 6% irradiance non-uniformity for the month of January.

bifacial field validation↗

PV degradation curves: non‐linearities and failure modes

Abstract Photovoltaic (PV) reliability and durability have seen increased interest in recent years. Historically, and as a preliminarily reasonable approximation, linear degradation rates have been used to quantify long‐term module and system performance. The underlying assumption of linearity can be violated at the beginning of the life, as has been well documented, especially for thin‐film technology. Additionally, non‐linearities in the wear‐out phase can have significant economic impact and appear to be linked to different failure modes. In addition, associating specific degradation and failure modes with specific time series behavior will aid in duplicating these degradation modes in accelerated tests and, eventually, in service life prediction. In this paper, we discuss different degradation modes and how some of these may cause approximately linear degradation within the measurement uncertainty (e.g., modules that were mainly affected by encapsulant discoloration) while other degradation modes lead to distinctly non‐linear degradation (e.g., hot spots caused by cracked cells or solder bond failures and corrosion). The various behaviors are summarized with the goal of aiding in predictions of what may be seen in other systems. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.