DOE OSTI · 1768302
Field-Array Benchmark of Commercial Bifacial PV Technologies with Publicly Available Data
Abstract
We present results for a 75-kW field array deployed with rows of 5 different commercially available bifacial technologies. Four PERC (multi and mono) and 1 Silicon Heterojunction manufacturers are represented. Reference strings of equivalent monofacial PV modules are also installed in the 10-row field. High accuracy string-level DC monitoring and module-level measurements have been recorded for six months. Analysis indicates performance within expectation, with a cumulative model mean error within +/- 2% for both bifacial and monofacial models and cumulative bifacial energy gain between 6-9%. A custom-module to measure shading loss from the torque-tube was installed. One month data shows up to 6% irradiance non-uniformity. A fixed-tilt test-site with 3 years of bifacial data is also presented, with a bifacial gain of 3%.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Ayala Pelaez, Silvana (ORCID:000000030180728X), Deline, Christopher (ORCID:0000000298678930), Marion, Bill (ORCID:0000000338456620), Sekulic, Bill, Parker, Joshua, McDanold, Byron, Stein, Joshua S.. 2021-01-05. Field-Array Benchmark of Commercial Bifacial PV Technologies with Publicly Available Data. https://doi.org/10.1109/pvsc45281.2020.9300379