Search NASA⌕ Search

DOE OSTI · 1724292

A physical unclonable neutron sensor for nuclear arms control inspections

Abstract

Abstract Classical sensor security relies on cryptographic algorithms executed on trusted hardware. This approach has significant shortcomings, however. Hardware can be manipulated, including below transistor level, and cryptographic keys are at risk of extraction attacks. A further weakness is that sensor media themselves are assumed to be trusted, and any authentication and encryption is done ex situ and a posteriori. Here we propose and demonstrate a different approach to sensor security that does not rely on classical cryptography and trusted electronics. We designed passive sensor media that inherently produce secure and trustworthy data, and whose honest and non-malicious nature can be easily established. As a proof-of-concept, we manufactured and characterized the properties of non-electronic, physical unclonable, optically complex media sensitive to neutrons for use in a high-security scenario: the inspection of a military facility to confirm the absence or presence of nuclear weapons and fissile materials.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Philippe, Sébastien (ORCID:0000000272827520), d’Errico, Francesco. 2020-11-26. A physical unclonable neutron sensor for nuclear arms control inspections. https://doi.org/10.1038/s41598-020-77459-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Safeguards Technology Program FY2026 Mid-Year Report for Project WBS# 24.1.3.3: Development of Procedures for Th-U Radiochronometry of Uranium Particles by LG-SIMS

Implementing 230 Th- 234 U radiochronometry of environmental uranium particles by large geometry secondary ion mass spectrometry (LG-SIMS) requires assessment, validation, and technical support before safeguards conclusions can be drawn from the information. This project investigates the most challenging aspects of LG-SIMS particle radiochronometry 230 Th- 234 U measurements through a collaboration between LANL and NIST, to provide best practices and procedures for determining high quality ages with optimized uncertainties. This includes exploration of reducing detector backgrounds, investigating the best ways to report uncertainties, and establishing recommended instrument setups.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FY26 Mid-Year Report

The goal of this project is to develop specific aspects of ultra-high-resolution microcalorimeter technologies that support IAEA Nuclear Material Laboratory needs and the goals of SP-1 19/NML-003 "Microcalorimetry Analysis Technique for NML" but are outside the scope of the SP-1. The focus is on commissioning, assembly, and testing of the microcalorimeter decay energy spectrometer with superconducting transition-edge sensors (TESs) and magnetic microcalorimeters (MMCs) in preparation for transfer to the IAEA Nuclear Material Laboratory.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗