A new diagnostic technique has been developed that couples a spectrometer and an image-intensified camera into the traditional motional Stark effect (MSE) system on DIII-D. The image-intensified camera syncs with the photo-elastic modulators to spectrally resolve the Stokes parameters across the Stark multiplet. Polarization dependent phase shift, likely from a plasma facing mirror, leads to the spectropolarimeter measuring a variation in the polarization angle across the MSE spectrum of ∼8°.
Keep this discovery
Explore connections, maps & timelines
Victor, B. S. (ORCID:0000000212512922), Allen, S. L., Holcomb, C. T. (ORCID:000000030680634X), Samuell, C. (ORCID:0000000239403697), Thorman, A. (ORCID:0000000159129325). 2021-04-01. Spectrally resolved polarization angle across the motional Stark effect spectrum. https://doi.org/10.1063/5.0040543