DOE OSTI · 1785952
EIC Hadron Beamline Vacuum Studies
Abstract
Ninety percent of the EIC hadron ring vacuum chamber consists of cold-bore sections running through and interconnecting 4.55 K RHIC superconducting (SC) magnets. The EIC operating specification requires shorter bunches and 3x higher intensity beams which are not appropriate for the present RHIC stainless steel cold-bore beam tube. The intensity and emittance of the hadron beams will degrade due to interactions with residual gas or vacuum instabilities arising from the expected resistive-wall (RW) heating, electron clouds, and beam-induced desorption mechanisms. Without strategies to limit RW heating, major cryogenic system modifications are needed to prevent SC magnet quenches. The SC magnet cold-bore beam tubes will be equipped with a high RRR copper-clad stainless steel screen to significantly reduce RW heating and so the effect on the SC magnet cryogenic heat load and temperature. A thin amorphous carbon film applied to the beam-facing copper surface will suppress electron cloud formation. This paper discusses the vacuum requirements imposed by the EIC hadron beams and the plans to achieve the necessary vacuum and thermal stability that ensure acceptable beam quality and lifetime.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Weiss, Daniel, Verdu-Andres, Silvia, Mapes, Michael, Tuozzolo, Joseph. 2021-05-19. EIC Hadron Beamline Vacuum Studies. https://doi.org/10.18429/jacow-ipac2021-wepab189
Cite the original work for its findings. Save a collection to share your selection of sources.