Abstract

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paranjothi, Gokulram, Odukomaiya, Adewale, Cui, Shuang, Bulk, Alexander. 2021-08-19. Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes. https://doi.org/10.1016/j.enbuild.2021.111372

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Maximizing the Benefits of On-Site Renewable Energy Generation Using On-Site Energy Storage

The commercial and industrial building sectors have a major role to play in a U.S. low-carbon future. Building owners can make a difference by deploying on-site renewable generation and storage technologies, which facilitates future-proofing their buildings as well as more effectively meeting the service requirements of the building. This resource provides an overview of common generation, storage, and load management technologies in behind-the-meter systems, and serves as a primer to demonstrate the impact on net building loads required from the grid for different sizes of renewable generation along with on-site electrical and thermal storage. These discussions can help commercial building owners communicate the value of these systems to project teams and develop innovative behind-the-meter solutions to achieve their energy goals.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Is a Generator the Only Solution When the Grid Fails? Optimizing Systems for Resiliency and Carbon Reduction: Preprint

Traditionally, buildings are dependent on utility infrastructure, and when a grid failure happens, end users rely on the closest source of energy storage to sustain operation until power is restored. For buildings, that typically means using an electric generator. This electric generator either uses on-site energy storage such as fossil fuels in a tank or a gas connection which is, in turn, tied to gas wells—also a form of energy storage. Generators are popular for their ease of implementation and low capital costs; however, they have limited value outside of disruptions, and they are a source of scope 1 emissions, or direct greenhouse gas emissions from sources controlled by the building owner. In contrast, some power generation and storage systems, such as photovoltaic (PV) panels and battery energy storage systems (BESS), can serve the same purpose during grid disruptions while presenting advantages outside of power failure. This paper explores methods for storing and converting energy on-site to increase building resiliency, focusing on solutions that minimize scope 1 emissions. We analyze the cost and carbon impacts of energy efficiency measures, PV arrays, and BESS, with and without generators, in a simulation test case. We find significant benefits can be achieved both during and outside of power failure events when designing systems that integrate the on-demand capability of generators, the low carbon energy supplied by PV, and the storage capabilities of BESS. Specifically, adding even minimal BESS and PV can result in downsizing the generator, increasing generator efficiency and requiring less fuel.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Medical Imaging Equipment Energy Efficiency

The energy use of medical imaging equipment (MIE) in healthcare facilities is estimated to be about 5% of total site energy use. MIE energy use is only expected to increase as technology advances and more patients seek services from MIE, enabling more facilities to install additional MIE. Healthcare organizations need reliable information regarding comprehensive energy use or lifetime energy costs with which to make energy-efficient MIE procurement decisions, and there are currently no MIE energy or efficiency standards in the United States (U.S.). This fact sheet provides background on MIE energy consumption, key terms, and guidance on why and how to meter MIE, helping stakeholders make informed decisions to enhance their facility's performance.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗