Air Pathway Dose Modeling for the E-Area Low-Level Waste Facility

Abstract

The US Department of Energy (DOE) Order 435.1 performance assessment (PA) process (USDOE 1999) prescribes a performance objective (10 mrem y -1 ) for evaluating atmospheric releases of radionuclides from DOE low-level waste (LLW) disposal facilities. The potential dose to an individual from exposure to radionuclides released into the atmosphere from LLW disposals can be estimated by application of radionuclide-specific dose-release factors (DRFs) (mrem Ci -1 ) to estimated flux rates (Ci y -1 ) at a particular time and location. In Revision 0 of this report, Lee (2006) calculated DRFs for potential atmospheric releases of 15 volatile radionuclides from seven ELLWF disposal units in support of the 2008 ELLWF PA (WSRC 2008). The mainframe version of the US Environmental Protection Agency’s (EPA) dose model CAP88 was used in the Revision 0 assessment. In Revision 1 of this report (Dixon and Minter 2017), the site-specific Savannah River National Laboratory (SRNL) atmospheric dose models MAXDOSE-SR version 2013 (Stone and Jannik 2013a) and MAXINE version 2017 (Bell 2017) were used to calculate DRFs for ten radionuclides. Revision 2 provided updated DRFs using the current version of the US Environmental Protection Agency’s (EPA) dose model CAP88-PC Version 4.1. After Revision 2 was finalized, DRFs were requested for Ar-37, Ar-39, Kr-83m, and Hg-206. Revision 3 provides the additional DRFs calculated using the same methods as used in Revision 2 of this document. The method for estimating new DRFs for the ELLWF disposal units is described in this report.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dixon, Kenneth L., Jannik, Gerald T.. 2021-08-01. Air Pathway Dose Modeling for the E-Area Low-Level Waste Facility. https://doi.org/10.2172/1821135

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part B)

ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗