Search NASA⌕ Search

DOE OSTI · 1864956

NorthStar Helium Cooling System. Final Report on LANL Contribution

Abstract

From the beginning of NNSA support to the NorthStar development of a production facility for the medical isotope Molybdenum-99 (Mo99), LANL has been responsible for the design and testing of a target and its cooling. The target is comprised of a stack of Mo100 disks separated by coolant flow gaps between the disks and between the first disk and a housing window, which separates the target and its coolant from the vacuum of the beam line. The target, and therefore its cooling requirements, evolved steadily over the years of system development

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Woloshun, Keith Albert, Olivas, Eric Richard. 2022-04-19. NorthStar Helium Cooling System. Final Report on LANL Contribution. https://doi.org/10.2172/1864956

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Novel Method for Domestic Stable Isotope Production (CRADA #667) Final Report

This report presents the progress achieved on our chlorine isotope separation efforts in the CRADA #667 agreement. We used a microchannel distillation (MCD) packing structure to enrich HCl isotopes (H35Cl, H37Cl) and an isotachophoresis (ITP) separation to enrich ionic chloride species (35Cl- and 37Cl-). A 2 m tall MCD column was constructed and achieved 264 separation stages over several days, which is well above the goal of 50 stages outlined in the CRADA. The resulting height equivalent to a theoretical plate (HETP) was 0.76 cm. ITP tests were run ~ 24 hours and achieved a single-stage separation factor of 1.559.

07 ISOTOPE AND RADIATION SOURCES↗