Search NASA⌕ Search

DOE OSTI · 1871438

Numerical Simulations of Non-Proliferation Experiments

Abstract

We have implemented a set of numerical simulations to numerically investigate the outcomes of non-proliferation experiments. The high explosive (HE) in the simulations is in the form of a cylinder. The two-dimensional simulations are carried out in the r-z cylindrical coordinate, and the three-dimensional simulation is in the Cartesian coordinate. From the simulation, the cavity formed after detonation stops its expansion after about 0.15 sec. At the time the cavity stops expanding, the cavity shape seems quite spherical although the initial HE is in the shape of cylinder, but the radius in the vertical direction, which is about 19.7m, is a little less than the one in the horizonal direction, which is about 21.5m. Although there is no layer of air between the HE and tuff in real experiments, in addition to the simulations without air, we add a layer of air in one simulation to assess any possible influence of the air on the shape of the cavity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dai, William Wenlong, Carney, Theodore Clayton, Pelak, Robert A., Peterson, Jeffrey Hammett, Cleveland, Kenneth Michael. 2022-05-31. Numerical Simulations of Non-Proliferation Experiments. https://doi.org/10.2172/1871438

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Safeguards Technology Program FY2026 Mid-Year Report for Project WBS# 24.1.3.3: Development of Procedures for Th-U Radiochronometry of Uranium Particles by LG-SIMS

Implementing 230 Th- 234 U radiochronometry of environmental uranium particles by large geometry secondary ion mass spectrometry (LG-SIMS) requires assessment, validation, and technical support before safeguards conclusions can be drawn from the information. This project investigates the most challenging aspects of LG-SIMS particle radiochronometry 230 Th- 234 U measurements through a collaboration between LANL and NIST, to provide best practices and procedures for determining high quality ages with optimized uncertainties. This includes exploration of reducing detector backgrounds, investigating the best ways to report uncertainties, and establishing recommended instrument setups.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

FY26 Mid-Year Report

The goal of this project is to develop specific aspects of ultra-high-resolution microcalorimeter technologies that support IAEA Nuclear Material Laboratory needs and the goals of SP-1 19/NML-003 "Microcalorimetry Analysis Technique for NML" but are outside the scope of the SP-1. The focus is on commissioning, assembly, and testing of the microcalorimeter decay energy spectrometer with superconducting transition-edge sensors (TESs) and magnetic microcalorimeters (MMCs) in preparation for transfer to the IAEA Nuclear Material Laboratory.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗