Search NASA⌕ Search

DOE OSTI · 1874247

Efficient Loads Surrogates for Waked Turbines in an Array

Abstract

Accurately and efficiently predicting wind turbine structural loading is a crucial step in wind farm design. Without considering structural loading, wind farm optimization could negatively impact turbine fatigue and ultimate loads, especially for waked and partially waked turbines, which could result in higher maintenance costs and reduced turbine lifetime. However, predicting turbine loads throughout an array is a costly step, as these quantities require time-accurate results across long time histories, which is often intractable for large array optimization. Therefore, surrogate models that link array spacing to load outputs are often used, but the surrogates are then unique to the inflow conditions and array configurations in the training library. This work develops surrogate models for many wind turbine load outputs based solely on rotor plane velocity measurements, with no required input about array configuration or freestream inflow parameters. Surrogate models were constructed for many turbine quantities of interest (QoI), considering mean, standard deviation, ultimate, and fatigue loads. In general, most QoI statistics were accurately captured, as measured by predicted vs. actual correlation coefficient, confirming the suitability of the approach. Temporal mean values of the QoI required only temporal mean measurements of the rotor plane inflow velocity. However, accurate prediction of temporal standard deviation, ultimate, and fatigue values of QoI also required temporal standard deviations of the rotor plane velocity field. Poor surrogate performance was observed when too many correlated inputs were used, such as multiple velocity components. If the fewest inflow parameters are used to construct the surrogates, the average correlation coefficient value for all output QoI statistics is 0.89. Surrogates for standard deviations and damage equivalent loads (DELs) of turbine QoIs generally had lower accuracy and tower-base and shaft load channels posed the most difficult to capture accurately. The results suggest that these surrogates could be easily paired with analytic wake models, which are frequently used for pre-construction wind farm array optimization, to account for turbine loading in addition to power production. By including the optimal inflow conditions, the surrogate accuracy can improve to an average correlation coefficient value for all output QoI statistics of 0.92. This work has established the ability to build accurate surrogates for mean, standard deviation, ultimate load, and DEL turbine QoI values based on the rotor plane inflow velocity, and identified which inflow conditions lead to greater surrogate accuracy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shaler, Kelsey, Jasa, John, Barter, Garrett E.. 2022-06-02. Efficient Loads Surrogates for Waked Turbines in an Array. https://doi.org/10.1088/1742-6596%2F2265%2F3%2F032095

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

An adaptive model-free robotic force control strategy for hydrodynamic real-time hybrid simulation of floating offshore wind turbines

Real-time hybrid simulation (RTHS) - a cyber-physical testing approach - promises to enhance the simulation fidelity of the model-scale experiments used to prototype floating offshore wind turbines (FOWTs). In hydrodynamic RTHS (hydro-RTHS), actuators emulate aerodynamic forces on model-scale FOWT specimens subjected to physical waves in a hydrodynamic laboratory. Robotic arms are promising candidates for actuation in hydro-RTHS due to their compact multi-degree-of-freedom (DOF) capabilities. Unlike classical RTHS for seismic applications, which typically relies on displacement control, hydro-RTHS requires 6-DOF force control on newly designed floating prototypes in a model-scale setting, which presents significant challenges, including modeling uncertainties, directional asymmetry, configuration drift, bandwidth limitations, and time-varying delays. To mitigate these constraints without extensive pre-test calibration, this study proposes an adaptive model-free robotic force control strategy that combines task-space explicit force control with a secondary joint-space pose-keeping task. The Adaptive Feedforward Compensator (AFC) is integrated into the force control loop to compensate for time-varying delay. Experimental testing was conducted using a Franka Emika Panda robotic arm with a 1:50 scale FOWT specimen under operational wind and wave conditions. Results demonstrate stable and consistent 6-DOF force tracking. Effective delay compensation was observed, with low-frequency delay reductions ranging from 71.4% to 91.8% and improvements in low-frequency surge force tracking of 25.0% to 52.1%. This study enhances robotic actuation performance in hydro-RTHS and introduces a force control strategy that supports reliable robotic operation in uncertain floating environments. Future work will explore disturbance-observer mechanisms to further enhance wave rejection capabilities under extreme wind and wave conditions.

17 WIND ENERGY↗

Computational capacity in hydrodynamic real-time hybrid simulation applied to simulate the dynamic response of floating offshore wind turbines

Real-time hybrid simulation (RTHS) mitigates similitude distortions in model-scale tests of floating offshore wind turbines (FOWTs) by coupling physical experiments with numerical models in real time. The coupling requires faster-than-real-time numerical computations to satisfy temporal similitude with the physical experiment, presenting a bottleneck for using more complex numerical models in RTHS. This paper presents a hydrodynamic-RTHS (hydro-RTHS) framework for FOWTs that simulates the hydrodynamics physically and the aerodynamics numerically with sensor feedback from the physical testing. The framework adapts the three-loop hardware architecture to leverage greater computational resources and mitigate strict temporal requirements, enabling more computationally demanding numerical analyses in hydro-RTHS. The three-loop hardware architecture integrates multiple machines, each dedicated to either numerical analysis or RTHS controls, with a rate-transition algorithm to synchronize the tasks executed across the different machine processors. Virtual and physical tests verified and validated the hydro-RTHS framework, respectively. The ”virtual” tests, which approximates the physical domain numerically, verified the RTHS framework with respect to a numerical full-scale complete FOWT model simulated in the open-source software, OpenFAST. The virtual tests were able to maintain comparable control signals while enabling greater computational resources for the numerical calculations. Real-world physical tests demonstrated that the hydro-RTHS framework computes aerodynamic forces similar to the complete OpenFAST model, validating the hydro-RTHS framework using the three-loop hardware architecture. Findings show that the hydro-RTHS framework with the three-loop hardware architecture is computationally efficient, with reserve capacity to simulate more complex problems due to the customized software, hardware, and rate-transition algorithm.

17 WIND ENERGY↗

Statistical Correlation of Heliostat Pointing Deviation With Wind

This work was carried out as part of the Heliostat Consortium (HelioCon) Field Deployment subtask with the aim to develop a reduced order model framework for correlating wind speed and pointing deviation of a heliostat facet. There are only sparse field measurements of heliostat pointing deviations and accompanying wind conditions published in the literature. Heliostat test standards, such as IEC 62862-4-3, propose a suite of tests including laser pointing repeatability at wind speeds below 4 m/s, and provide technical requirements for heliostat slope and tracking deviations in coarse average wind speed bins of 4 m/s, 6 m/s, and 8 m/s. In addressing the gap of the variation of heliostat pointing deviation with wind speed, field measurements of laser pointing on a grid target and wind conditions were analyzed in this study at the Third-Party Metrology Platform at the National Laboratory of the Rockies (NLR) Flatirons Campus. Horizontal pointing deviations were found to follow a logarithmic relationship with peak wind speed, whereas vertical pointing deviations follow an exponential relationship with peak wind speed. Both horizontal and vertical pointing deviations also follow a second order polynomial relationship, as expected from the proportionality of elastic loads and deformations with the square of wind speed. The results indicate that heliostat facet pointing deviations in the vertical direction increase at a faster rate than in the horizontal direction with increasing wind speed over the tested range, however these are dependent on the heliostat structural design. Next steps are recommended for additional field measurements to confirm a linear relationship of pointing deviation with applied moment on a heliostat facet, and to distinguish between gravity-induced and wind-induced pointing deviations at different elevation angles. The derived correlations in the preliminary analysis in this report serve as a case study for heliostat developers and plant operators to estimate the wind-induced pointing deviations and their variation with peak gust wind speed. Next steps in future work would recommend higher resolution and longer duration datasets for different elevation angles and wind directions to reduce uncertainties and variance of collected laser beam spot data and their correlations with bin-averaged wind speed.

17 WIND ENERGY↗