DOE OSTI · 1886891
A poloidal high- k scattering system for NSTX-U
Abstract
A previous 5-channel tangential high-k scattering system is being replaced by an 8-channel, poloidal high-k scattering system on the National Spherical Torus eXperiment Upgrade (NSTX-U) device located in Princeton, NJ, USA. The 693 GHz poloidal scattering system replaces a 280 GHz tangential scattering system to study high-k electron density fluctuations on NSTX-U, thereby considerably enhancing planned turbulence physics studies by providing a measurement of the k θ -spectrum of both electron temperature gradient (ETG) and ion temperature gradient (ITG) modes. Two approaches to generating the 693 GHz probe beam are under development: an optically-pumped far-infrared (FIR) laser that generates ~50 mW, and a compact gyrotron that can potentially generate in excess of 5 W. Large aperture optics collect radiation scattered from density fluctuations in the plasma core at 8 simultaneous scattering angles ranging from 2 to 15° corresponding to poloidal wavenumbers that extend to >40 cm -1 . Finally, steerable launch optics coupled with receiver optics mounted on a 5-axis receiver carriage allow the scattering volume to be placed radially from r/a = 0.3 out to the pedestal region (r/a ~ 0.99) and translated horizontally as needed to satisfy wavenumber matching.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Domier, C. W., Dannenberg, J., Zhu, Y., Liu, X., Sirigiri, J. R., Ren, Y., Stratton, B., Luhmann, N. C.. 2022-01-05. A poloidal high- k scattering system for NSTX-U. https://doi.org/10.1088/1748-0221%2F17%2F01%2Fc01018
Cite the original work for its findings. Save a collection to share your selection of sources.