Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams

Abstract

Monitoring of cooling tower performance in a nuclear reactor facility is necessary to ensure safe operation; however, instrumentation for measuring performance characteristics can be difficult to install and may malfunction or break down over long duration experiments. This paper describes employing a thermodynamic approach to quantify cooling tower performance, the Merkel model, which requires only five parameters, namely, inlet water temperature, outlet water temperature, liquid mass flowrate, gas mass flowrate, and wet bulb temperature. Using this model, a general method to determine cooling tower operation for a nuclear reactor was developed in situations when neither the outlet water temperature nor gas mass flowrate are available, the former being a critical piece of information to bound the Merkel integral. Furthermore, when multiple cooling tower cells are used in parallel (as would be in the case of large-scale cooling operations), only the average outlet temperature of the cooling system is used as feedback for fan speed control, increasing the difficulty of obtaining the outlet water temperature for each cell. To address these shortcomings, this paper describes a method to obtain individual cell outlet water temperatures for mechanical forced-air cooling towers via parametric analysis and optimization. In this method, the outlet water temperature for an individual cooling tower cell is acquired as a function of the liquid-to-gas ratio (L/G). Leveraging the tight tolerance on the average outlet water temperature, an error function is generated to describe the deviation of the parameterized L/G to the highly controlled average outlet temperature. The method was able to determine the gas flowrate at rated conditions to be within 3.9% from that obtained from the manufacturer’s specification, while the average error for the four individual cooling cell outlet water temperatures were 1.6 °C, -0.5 °C, -1.0 °C, and 0.3 °C.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Katinas, Christopher, Reichardt, Thomas, d’Entremont, Brian, Ray, William, Willis, Michael, Kulp, Thomas. 2022-10-14. Calculation of Nuclear Reactor Cooling Tower Performance With Limited Data Streams. https://doi.org/10.1115/1.4055746

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗