Search NASA⌕ Search

DOE OSTI · 1971716

Implementation of Distributed Memory Computing in MOSAIC to Enable Large 3D Simulations of Irradiated Concrete

Abstract

The concrete biological shield (CBS) of light-water reactors protects workers and the surrounding environment by absorbing neutron and gamma irradiation emitted from the reactor core. The radiation dose increases with the CBS’s operational time and, in the long term, becomes significant enough to raise the question of irradiation effects on concrete—and particularly on the structural integrity of the CBS. Irradiation-induced damage has been identified as one of the main degradation mechanisms in the CBS. Neutron radiation causes the swelling of aggregate-forming minerals at different rates and amplitudes depending on the mineral’s nature. Silicate-bearing minerals such as quartz are particularly sensitive to neutron radiation and experience up to 17.8% volumetric expansion. Aggregates comprise several minerals with different orientations and are, therefore, subject to cracking as a result of mismatch strains. Additionally, the swelling of aggregates creates significant stresses in the surrounding cement paste matrix, which also results in crack formation. In parallel with the collection of characterization and irradiation test data, development of modeling and simulation tools for irradiated concrete is ongoing with the support of the US Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) program. This effort resulted in the development and application of the fast-Fourier transform (FFT)–based code Microstructure-Oriented Scientific Analysis of Irradiated Concrete (MOSAIC) at Oak Ridge National Laboratory.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Henderson, Shane C., Cheniour, Amani, Le Pape, Yann. 2023-03-01. Implementation of Distributed Memory Computing in MOSAIC to Enable Large 3D Simulations of Irradiated Concrete. https://doi.org/10.2172/1971716

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part B)

ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗