Search NASA⌕ Search

DOE OSTI · 1997222

Reservoir Thermal Energy Storage Benchmarking (Rev. 3)

Abstract

A benchmarking analysis of RTES research funded by GTO through the Beyond Batteries projects was conducted against the ESGC to see where they fit within the identified ESGC Use Cases. The projects were found to advance knowledge in multiple ESGC use cases, either directly or in some cases, indirectly as enabling technologies. This analysis is helpful to understand where RTES and associated research fits into the larger discussion around energy storage technologies. Also, a retrospective analysis of the Beyond Batteries projects was conducted to evaluate what the projects learned and how the results can be applied to advance the value of RTES. Major results of each of the studies are summarized in Table 2. Additionally, a comparative metrics analysis for RTES was completed to understand where RTES lies within the energy storage industry. Metrics for evaluation of RTES and its comparison to other storage technologies were selected and ranges of their values compiled. The selected metrics – LCOE (levelized cost of energy), capital costs, roundtrip efficiency, energy storage capacity, and storage time – were chosen based on data availability and have a particularly strong influence on the potential deployment of a storage technology. Charts which compare the metrics are presented in section 4.3 and show ranges for each of the 10 selected technologies. However, due to a lack of domestic operational facilities, values for RTES and for portions of the remaining technologies are based on theoretical modeling and studies of best-case scenarios. LCOE estimates for RTES fall within the lower reaches of Figure 15, but nevertheless amount to 2 – 5 times the ESGC Roadmap goal for LCOE, for example in the Facilitating and Evolving Grid Use Case. Capital costs for RTES sit on the higher end (Figure 16) but are expected to decrease as new projects are developed and the technology is refined. The theoretical roundtrip efficiency reported for RTES varies from mid to high percentages (Figure 17) with efficiencies upwards of 93% in modeled scenarios in the Portland Basin (Bershaw et al.,2020). RTES is also expected to have the largest energy storage capacities and longest storage times, likely matched only by lower efficiency hydrogen storage. To better assess the role that RTES could play in energy storage we examined it’s potential in the U.S. The potential depends on many factors. Recently, many researchers have started looking at deep sedimentary basins, depleted oil and gas fields, and basalt formations as potential targets for RTES development. The United States Geological Survey (USGS) has analyzed various cities and shown substantial RTES potential in the cooling sector (Pepin et al., 2021). By modeling RTES in low-quality groundwater (e.g., brackish), it is shown to be favorable across the U.S. with particular suitability in the Illinois Basin, Coastal Plains, and Basin and Range regions. Seasonal RTES operations have also been modeled in the Portland Basin by those at the USGS and Portland State University to simulate an RTES system supplying heating loads needed for the Oregon Health and Science University. Simulations suggest that high conductive heat loss in the initial years exists but tends to decrease with increasing time and development of the resource due to self-insulating nature of the basalts (Burns et al., 2020). Other national laboratory efforts are taking a close look at many of the technical issues involved with RTES (McLing et al., 2019, McLing et al., 2022). These include difficulties in understanding geochemical, hydrogeological, mechanical, and microbiological changes at such elevated temperatures and operational scenarios. Major gaps in research are identified and suggested for future work. With this increased focus to understand how to make RTES successful in the U.S., this technology could be a potential solution to many of the nation’s energy storage problems. For the energy independence of this country, the DOE should prioritize de-risking this technology by making future investments in pilot-scale demonstrations to attract potential investors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ginosar, Daniel M., Atkinson, Trevor A., Adhikari, Birendra, Toman, Jakub N. M. N., Podgorney, John. 2023-08-24. Reservoir Thermal Energy Storage Benchmarking (Rev. 3). https://doi.org/10.2172/1997222

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

15 GEOTHERMAL ENERGY↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗