Search NASA⌕ Search

DOE OSTI · 21036180

An automated intensity-weighted brachytherapy seed localization algorithm

Abstract

Brachytherapy has proven to be an effective treatment for various forms of cancer, whereby radioactive material is inserted directly into the body to maximize dosage to malignant tumors while preserving healthy tissue. In order to validate the preoperative or intraoperative dosimetric model, a postimplant evaluation procedure is needed to ensure that the locations of the implanted seeds are consistent with the planning stage. Moreover, development of an automated algorithm for seed detection and localization is necessary to expedite the postimplant evaluation process and reduce human error. Most previously reported algorithms have performed binary transforms on images before attempting to localize seeds. Furthermore, traditional approaches based upon three-dimensional seed shape parameterization and matching require high resolution imaging. The authors propose a new computationally efficient algorithm for automatic seed localization for full three-dimensional, low-resolution data sets that directly applies voxel intensity to the estimation of both seed centroid location and angular seed orientation. Computer simulations, phantom studies, and in vivo computed tomography prostate seed imaging results show that the proposed algorithm can produce reliable results even for low-resolution images.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Whitehead, Gregory, Zheng, Chang, Ji, Jim. 2008-03-15. An automated intensity-weighted brachytherapy seed localization algorithm. https://doi.org/10.1118/1.2836418. https://searchnasa.com/record/osti%3A21036180/an-automated-intensity-weighted-brachytherapy-seed-localization-algorithm

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search NASA by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Cross sections of 147–149 Sm( 6 Li,x) reactions for the production of 149 Tb for targeted alpha therapy

Terbium-149g (t 1/2 = 4.12 h) is of particular interest for targeted alpha therapy cancer treatment due to its ability to decay via both alpha and positron emission, making it a potential theranostic nuclide. Due to many challenges facing its production, there are limited facilities worldwide that have demonstrated the ability to produce this nuclide in quantities sufficient for medical research. Since the Cyclotron Institute at Texas A&M University is a specialized accelerator facility capable of accelerating a wide variety of ions, we are investigating production pathway options. One of the major challenges facing its production is the known co-production of the excited isomeric state, 149m Tb (t 1/2 = 4.1 min). However, this state does not decay to the ground state of 149g Tb, negating any potential contribution to its yield. Due to its short-half life, the cross section for the population of this state has never been measured. After calculating several potential reaction yields using predictive models, the reactions of 147–149 Sm( 6 Li,xn) 149 Tb were identified as candidates. Lithium-6 beams of varied energies between 45-65 MeV were impinged on enriched 147 Sm, 148 Sm, and 149 Sm targets at the Cyclotron Institute at Texas A&M University, and the reaction products were measured immediately following irradiation using high-purity germanium detectors, enabling detection of both 149m Tb and 149g Tb. Cross sections for all nuclides produced in sufficient activity in these reactions were also measured and reported here. We conclude that the population of 149m Tb is much preferred over population of the ground state for these 6 Li-induced reactions, and it is necessary to explore other options for 149g Tb production.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗